Print

Overview

Scope

This guide is intended for properly trained service personnel and technicians who need to install Arista Networks Data Center Switches.

DCS-7050QX-32S DCS-7050TX-48 DCS-7050QX2-32S
DCS-7050TX-64 DCS-7050SX-64 DCS-7050TX-72
DCS-7050SX-72 DCS-7050TX-72Q DCS-7050SX-72Q
DCS-7050TX-96 DCS-7050SX2-72Q DCS-7050SX-96
DCS-7050CX3-32S DCS-7050SX3-48YC12 DCS-7050SX3-48YC8
DCS-7050CX3M-32S DCS-7050TX3-48C8 DCS-7050SX3-48C8
Important: Only qualified personnel should install, service, or replace this equipment.

Seul le personnel qualifié doit installer, service, ou remplacer cet équipement.

Receiving and Inspecting the Equipment

Upon receiving the switch, inspect the shipping boxes and record any external damage. Retain packing materials if you suspect that part of the shipment is damaged; the carrier may need to inspect them.

If the boxes were not damaged in transit, unpack them carefully. Ensure that you do not discard any accessories that may be packaged in the same box as the main unit.

Inspect the packing list and confirm that you received all listed items. Compare the packing list with your purchase order. Parts List provides a list of components included with the switch.

Installation Process

The following tasks are required to install and use the switch.

  1. Select and prepare the installation site (Site Selection).
  2. Assemble the installation tools listed (Tools and Parts Required for Installation).
  3. Attach the mounting brackets and install the switch in an equipment rack (Rack Mounting the Switch).
  4. Connect the switch to the power source and network devices (Cabling the Switch).
  5. Configure the switch (Configuring the Switch).
    Important: Class 1 Laser Product: This product has provisions to install Class 1 laser transceivers which provide optical coupling to the communication network. Once a Class 1 laser product is installed, the equipment is a Class 1 Laser Product (Appareil à Laser de Classe 1). The customer is responsible for selecting and installing the Class 1 laser transceiver and for insuring that the Class 1 AEL (Allowable Emission Limit) per EN/IEC 60825, CSA E60825-1, and Code of Federal Regulations 21 CFR 1040 is not exceeded after the laser transceiver have been installed. Do not install laser products whose class rating is greater than 1. Refer to all safety instructions that accompanied the transceiver prior to installation. Only Class 1 laser devices, certified for use in the country of installation by the cognizant agency are to be utilized in this product.

     

    Produit Laser de classe 1: Ce produit a des dispositions pour installer des émetteurs-récepteurs de laser de classe 1 qui offre de couplage au réseau de communication optique.Une fois un produit laser de classe 1 est installé, l'équipement est un produit Laser de classe 1 (Appareil à Laser de Classe 1).Le client est responsable pour sélectionner et installer l'émetteur/récepteur de laser de classe 1 et pour assurer que la classe 1 AEL (limite d'émission admissible) par EN/IEC 6-825, CSA E60825-1, et Code des règlements fédéraux 21 CFR 1040 ne soit pas dépassée après avoir installé l'émetteur/récepteur de laser. Ne pas installer des appareils à laser dont la cote de classe est supérieure à 1.Voir toutes les consignes de sécurité qui ont accompagné l'émetteur-récepteur avant l'installation. Seuls appareils laser de classe 1 certifiés pour une utilisation dans le pays d’installation par l’organisme compétent doivent être utilisées dans ce produit.

    Important: Ultimate disposal of this product should be handled in accordance with all national laws and regulations.

    Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien qualifié.

Obtaining Technical Assistance

Any customer, partner, reseller or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways.

Important: No user serviceable parts inside. Refer all servicing to qualified service personnel.

Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien qualifié.

Specifications

List of specifications of Arista Data Center modular switches and components covered by this guide.

Table 1. Switch Specifications (Dimensions and Weights)
Switch Size (W x H x D) Weight
DCS-7050QX-32S 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 9.1 kg (20.1 lbs.)
DCS-7050TX-48 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 7.7 kg (17.0 lbs.)
DCS-7050QX2-32S 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 9.1 kg (20.1 lbs.)
DCS-7050TX-64 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 8.6 kg (19.0 lbs.)
DCS-7050SX-64 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 8.6 kg (19.0 lbs.)
DCS-7050TX-72 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 20.6 inches) 10.0 kg (22.0 lbs.)
DCS-7050SX-72 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 8.6 kg (19.0 lbs.)
DCS-7050TX-72Q 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 20.6 inches) 10.2 kg (22.5 lbs.)
DCS-7050SX-72Q 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 7.8 kg (17.2 lbs.)
DCS-7050TX-96 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 20.6 inches) 10.5 kg (23.1 lbs.)
DCS-7050SX2-72Q 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 10.1 kg (22.3 lbs.)
DCS-7050SX-96 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 9.1 kg (20.1 lbs.)
DCS-7050CX3-32S 48.3 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches) 8.8 kg (19.4 lbs.)
DCS-7050SX3-48YC12 48.3 x 4.4 x 44.4 cm (19 x 1.75 x 17.5 inches) 9.2 kg (20.3 lbs.)
DCS-7050SX3-48YC8 48.3 x 4.4 x 46.8 cm (19 x 1.75 x 18.43 inches)(1) 9.5 kg (21.0 lbs.)
DCS-7050CX3M-32S 48.3 x 4.4 x 55.9 cm (19 x 1.75 x 22.0 inches) 12.0 kg (26.5 lbs.)
DCS-7050TX3-48C8 48.3 x 4.4 x 46.7 cm (19 x 1.75 x 18.4 inches) 9.4 kg (20.6 lbs.)
DCS-7050SX3-48C8 48.3 x 4.4 x 46.8 cm (19 x 1.75 x 18.4 inches)(1) 9.4 kg (20.6 lbs.)

(1): Depth 50.5 cm (19.9 inches) with PSU and fans.

 

 

Table 2. Switch Specifications (Operational and Storage)
Switch Operating Temperature Storage Temperature Operating Altitude Relative Humidity
All 0° to 40°C (32° to 104°F) -25° to 70°C (-13° to 158°F) 0 to 3,000 meters (0 to 10,000 feet) 5 to 90% (non-condensing)

 

 

Table 3. Switch Specifications (Power Input)
Power Source PSU Models Ratings
Power Input (AC Power) PWR-500AC 100 - 240 VAC, 6.5 to 3.0 A, 50/60 Hz
Power Input (DC Power) PWR-500-DC -48 to -60 VDC, 15 A
Power Input (AC Power) PWR-511-AC 100 - 127 / 200 - 240 VAC, 7.1 / 3.4 A, 50/60 Hz
Power Input (DC Power) PWR-511-DC -48 to -60 VDC, 13 A
Power Input (AC Power) PWR-1011-AC-RED 100 - 120 / 200 - 240 VAC, 12 / 6 A, 50/60 Hz
Power Input (DC Power) PWR-1011-DC-RED -48 to -60 VDC, 30 A
Note: All PSU models are not supported by all switches. Some switches described in this guide could use power supplies that may no longer be available. Contact your local Arista representative for more information.

 

 

Table 4. Switch Specifications (Power Draw)
Switch Power Draw (Typical / Maximum) Supported Power Supply
DCS-7050QX-32S 150 W / 300 W PWR-500AC, PWR-500-DC
DCS-7050TX-48 305 W / 367 W PWR-500AC, PWR-500-DC
DCS-7050QX2-32S 129 W / 283 W PWR-500AC, PWR-500-DC
DCS-7050TX-64 315 W / 387 W PWR-500AC, PWR-500-DC
DCS-7050SX-64 140 W / 220 W PWR-500AC, PWR-500-DC
DCS-7050TX-72 349 W / 440 W PWR-500AC, PWR-500-DC
DCS-7050SX-72 144 W / 276 W PWR-500AC, PWR-500-DC
DCS-7050TX-72Q 340 W / 430 W PWR-500AC, PWR-500-DC
DCS-7050SX-72Q 144 W / 261 W PWR-500AC, PWR-500-DC
DCS-7050TX-96 355 W / 455 W PWR-500AC, PWR-500-DC
DCS-7050SX2-72Q 127 W / 251 W PWR-500AC, PWR-500-DC
DCS-7050SX-96 159 W / 290 W PWR-500AC, PWR-500-DC
DCS-7050CX3-32S 206 W / 314 W PWR-500AC, PWR-500-DC
DCS-7050SX3-48YC12 170 W / 325 W PWR-500AC, PWR-500-DC
DCS-7050SX3-48YC8 165 W / 345 W PWR-511-AC, PWR-511-DC
DCS-7050CX3M-32S 398 W / 751 W PWR-1011-AC-RED, PWR-1011-DC-RED
DCS-7050TX3-48C8 212 W / 346 W PWR-511-AC, PWR-511-DC
DCS-7050SX3-48C8 133 W / 313 W PWR-511-AC, PWR-511-DC
..