1.1 Scope
This guide is intended for properly trained service personnel and technicians who need to install the following Arista Networks Data Center Switches:
DCS-7304
DCS-7304X3
DCS-7308
DCS-7308X3
DCS-7316
 
DCS-7324
 
DCS-7328
 
Important! Only qualified personnel should install, service, or replace this equipment.

Seul le personnel qualifié doit installer, service, ou remplacer cet équipement.
1.2 Receiving and Inspecting the Equipment
Upon receiving the switch, inspect the shipping boxes and record any external damage. Retain packing materials if you suspect that part of the shipment is damaged; the carrier may need to inspect them.
If the boxes were not damaged in transit, unpack them carefully. Ensure that you do not discard any accessories that may be packaged in the same box as the main unit.
Inspect the packing list and confirm that you received all listed items. Compare the packing list with your purchase order. Appendix C provides a list of components included with the switch.
1.3 Installation Process
The following tasks are required to install and use the switch:
Step 1 Select and prepare the installation site ( Section 2.1).
Step 2 Assemble the installation tools listed ( Section 2.2).
Step 3 Attach the mounting brackets and install the switch in an equipment rack ( Chapter 3).
Step 4 Connect the switch to the power source and network devices ( Chapter 4 and Chapter 5).
Step 5 Configure the switch ( Chapter 6).
Important! Class 1 Laser Product: This product has provisions to install Class 1 laser transceivers that provides optical coupling to the communication network. Once a Class 1 laser product is installed, the equipment is a Class 1 Laser Product (Appareil à Laser de Classe 1). The customer is responsible for selecting and installing the Class 1 laser transceiver and for insuring that the Class 1 AEL (Allowable Emission Limit) per EN/IEC 6-825, CSA E60825-1, and Code of Federal Regulations 21 CFR 1040 is not exceeded after the laser transceiver have been installed. Do not install laser products whose class rating is greater than 1. Refer to all safety instructions that accompanied the transceiver prior to installation. Only Class 1 laser devices certified for use in the country of installation by the cognizant agency are to be utilized in this product.

Produit Laser de classe 1: Ce produit a des dispositions pour installer des émetteurs-récepteurs de laser de classe 1 qui offre de couplage au réseau de communication optique.Une fois un produit laser de classe 1 est installé, l'équipement est un produit Laser de classe 1 (Appareil à Laser de Classe 1).Le client est responsable pour sélectionner et installer l'émetteur/récepteur de laser de classe 1 et pour assurer que la classe 1 AEL (limite d'émission admissible) par EN/IEC 60825, CSA E60825-1, et Code des règlements fédéraux 21 CFR 1040 ne soit pas dépassée après avoir installé l'émetteur/récepteur de laser. Ne pas installer des appareils à laser dont la cote de classe est supérieure à 1.Voir toutes les consignes de sécurité qui ont accompagné l'émetteur-récepteur avant l'installation. Seuls appareils laser de classe 1 certifiés pour une utilisation dans le pays d’installation par l’organisme compétent doivent être utilisées dans ce produit.
Important! Ultimate disposal of this product must be handled in accordance with all national laws and regulations.

Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien qualifié.
The fabric module requires special handling when removing, inserting, or handling the component. Appendix B provides instructions for handing fabric modules.
1.4 Safety Information
Refer to the Arista Networks document Safety Information and Translated Safety Warnings available at:
1.5 Obtaining Technical Assistance
Any customer, partner, reseller or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways:
Email: support@arista.com. This is the easiest way to create a new service request.
Include a detailed description of the problem and the output of “show tech-support”.
A support case may be created through the support portal on our website. You may also download the most current software and documentation, as well as view FAQs, Knowledge Base articles, Security Advisories, and Field Notices.
Phone: +1 866-476-0000 or +1 408-547-5502.
Important! No user serviceable parts inside. Refer all servicing to qualified service personnel.

Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien qualifié.
1.6 Specifications
Table 1-1 lists specifications of Arista Data Center modular switches and components covered by this guide.
Table 1-1 7300 Modular Switch and Component Specifications
 
DCS-7304/7324/7304X3
DCS-7308/7328/7308X3
DCS-7316
Height
8 RU: 353mm (13.9 inches)
13 RU: 572 mm (22.5 inches)
21 RU: 930 mm (36.6 inches)
Width
442 mm (17.4 inches)
442 mm (17.4 inches)
442 mm (17.4 inches)
Depth
602 mm (23.7 inches)
602 mm (23.7 inches)
706 mm (27.8 inches)
Weight
Empty
36 kg (78 lbs)
50 kg (110 lbs)
81 kg (178 lbs)
Fully Loaded
89 kg (196 lbs)
140 kg (309 lbs)
244 kg (536 lbs)
Input Power (per circuit)
AC Power
200 - 240 VAC, 16 A (20 A US), 50 or 60 Hz
200 - 240 VAC, 16 A (20 A US), 50 or 60 Hz
200 - 240 VAC, 16 A (20 A US), 50 or 60 Hz
DC Power
-48 - -60 VDC, 80 A
-48 - -60 VDC, 80 A
-48 - -60 VDC, 80 A
Branch Circuit Protection
AC Power
20 A
20 A
20 A
DC Power
100 A
100 A
100 A
Input Power Circuits
1 to 4 circuits
2 to 6 circuits
3 to 8 circuits
Operating Temperature
Storage Temperature
Operating Altitude
Relative Humidity
0° to 40°C (32° to 104°F)
-40° to 70°C (-40° to 158°F)
0 to 3,000 meters
(0 to 10,000 feet)
 
5 to 90%
0° to 40°C (32° to 104°F)
-40° to 70°C (-40° to 158°F)
0 to 3,000 meters
(0 to 10,000 feet)
 
5 to 90%
0° to 40°C (32° to 104°F)
-40° to 70°C (-40° to 158°F)
0 to 3,000 meters
(0 to 10,000 feet)
 
5 to 90%
Cooling
6000 W maximum
9000 W maximum
12000 W maximum
Table 1-2 lists power specifications of modular switch components.
Table 1-2 7300 Series Power Specifications
Module Type
Part Number
Power Draw/ Typical Maximum
Supervisor Modules
DCS-7300(-D)-SUP
DCS-7300-SUP2-D
65 W / 80 W
100 W / 152 W
Linecard Modules
DCS-7300X-32Q-LC
DCS-7300X-64S-LC
DCS-7300X-64T-LC
DCS-7320X-32C-LC
DCS-7300X3-32C-LC
DCS-7300X3-48YC4-LC
219 W / 372 W
166 W / 232 W
279 W / 430 W
428 W / 516 W
284 W / 491 W
193 W / 228 W
Fabric Modules
DCS-7304X-FM
DCS-7308X-FM
DCS-7316X-FM
DCS-7324X-FM
DCS-7328X-FM
DCS-7304X3-FM
DCS-7308X3-FM
98 W / 172 W
195 W / 343 W
550 W / 760 W
192W / 288 W
380W / 578 W
98 W / 172 W
195 W / 343 W
Fan-Only Modules
DCS-7304-S-FAN
DCS-7308-S-FAN
16 W / 32 W
32 W / 64 W
Power Supplies
PWR-2700-DC (fan power)
PWR-3K-AC (fan power)
PWR-3KT-AC (fan power)
PWR-3K-DC (fan power)
43 W/ 43 W
43 W/ 43 W
43 W/ 43 W
43 W/ 43 W
7304 Series System
Full chassis loaded with four
DCS-7300X-64T-LC line cards
1573 W / 3048 W
7308 Series System
Full chassis loaded with eight
DCS-7300X-64T-LC line cards
3077 W / 4972 W
7316 Series System
Full chassis loaded with Sixteen
DCS-7300X-64T-LC line cards
6729 W / 10080 W
7324X Series System
Full chassis loaded with four
DCS-7320X-32C-LC line cards
2545 W / 3376 W
7328X Series System
Full chassis loaded with eight
DCS-7320X-32C-LC line cards
5009 W / 6600 W
7304X3 Series System
Full chassis loaded with four
DCS-7300X3-32C-LC line cards
1885 W / 3078 W
7308X3 Series System
Full chassis loaded with eight
DCS-7300X3-32C-LC line cards
4005 W / 6490 W
 
Table 1-3 lists 7300X Series switch components.
Table 1-3 7300X Series
Chassis Model
Fabric Module
Fan-only Module
Fan Spare
Line Card
Power Supply
DCS-7304 (Forward)
DCS-7304X-FM-F
DCS-7304-S-FAN-F
FAN-7002-F
DCS-7300X-32Q-LC
DCS-7300X-64S-LC
DCS-7300X-64T-LC
PWR-3K-AC-F
PWR-2700-DC-F
DCS-7304 (Reverse)
DCS-7304X-FM-R
DCS-7304-S-FAN-R
FAN-7002-R
DCS-7300X-32Q-LC
DCS-7300X-64S-LC
DCS-7300X-64T-LC
PWR-3K-AC-R
PWR-2700-DC-R
DCS-7308 (Forward)
DCS-7308X-FM-F
DCS-7308-S-FAN-F
FAN-7002-F
DCS-7300X-32Q-LC
DCS-7300X-64S-LC
DCS-7300X-64T-LC
PWR-3K-AC-F
PWR-2700-DC-F
DCS-7308 (Reverse)
DCS-7308X-FM-R
DCS-7308-S-FAN-R
FAN-7002-R
DCS-7300X-32Q-LC
DCS-7300X-64S-LC
DCS-7300X-64T-LC
PWR-3K-AC-R
PWR-2700-DC-R
DCS-7316 (Forward)
DCS-7316X-FM-F
Not Available
FAN-7002-F
DCS-7300X-32Q-LC
DCS-7300X-64S-LC
DCS-7300X-64T-LC
PWR-3K-AC-F
PWR-2700-DC-F
PWR-3K-AC-R
PWR-2700-DC-R
DCS-7316 (Reverse)
DCS-7316X-FM-R
Not Available
FAN-7002-R
DCS-7300X-32Q-LC
DCS-7300X-64S-LC
DCS-7300X-64T-LC
PWR-3K-AC-F
PWR-2700-DC-F
PWR-3K-AC-R
PWR-2700-DC-R
Table 1-4 lists 7320X Series switch components.
Table 1-4 7320X Series
Chassis Model
Fabric Module
Fan Spare
Line Card
Power Supply
DCS-7324X (Forward)
DCS-7324X-FM-F
FAN-7002H-F
DCS-7320X-32C-LC
PWR-3KT-AC-BLUE
DCS-7328X (Forward)
DCS-7328X-FM-F
FAN-7002H-F
DCS-7320X-32C-LC
PWR-3KT-AC-BLUE
 
Table 1-5 lists 7300X3 Series switch components.
Table 1-5 7320X3 Series
Chassis Model
Fabric Module
Fan Spare
Line Card
Power Supply
DCS-7304X3
DCS-7304X3-FM
FAN-7002H-F
DCS-7300X3-32C-LC
PWR-3KT-AC-BLUE
DCS-7308X3
DCS-7308X3-FM
FAN-7002H-F
DCS-7320X-32C-LC
PWR-3KT-AC-BLUE
Table 1-6 lists an AC and DC power supply unit (PSU) comparison of circuit, cabling, and airflow for the DCS-7304, DCS-7308, and DCS-7316.
Table 1-6 AC/DC PSU comparison (Circuit, Cabling, and Airflow for DCS-7304, DCS-7308, and DCS-7316)
Model
Supported Chassis
Input Power (Per Circuit)
Branch Circuit Protection
Required Cabling and Interconnect
Description
Qty
PSU Air Flow
PWR-3K-AC-R
PWR-3K-AC-F
DCS-7304
DCS-7308
DCS-7316
200 - 240 VAC
16 A (20 A US)
50 or 60 Hz
20 A
Power cables:
14 AWG, C19-C20
One for each AC power supply module supplied with switch.
Reverse (Red)
Forward (Blue)
PWR-3KT-AC-
BLUE
DCS-7304
DCS-7308
200 - 240 VAC
16 A (20 A US)
50 or 60 Hz
20 A
Power cables:
14 AWG, C19-C20
One for each AC power supply module supplied with switch.
Forward (Blue)
PWR-2700-DC-R
PWR-2700-DC-F
DCS-7304
DCS-7308
DCS-7316
-48 to -60 VDC
80 A
100 A
DC Adapter (Arista part number CON-00581)
2 hole compression lug (not included)
One DC adapter per power supply
2 compression lugs per DC Adapter
Reverse (Red)
Forward (Blue)
PWR-3K-DC-
BLUE
DCS-7304
DCS-7308
-48 to -60 VDC
82.5 A
100 A
2 hole compression lug (not included)
2 compression lugs per DC Adapter
Forward (Blue)
Table 1-7 lists the power supply setup for LED status indicators.
Table 1-7 Power Supply Setup for LED Status
Power Supply
State
LED
Name
PWR-3K-AC-Blue
PWR-3KT-AC-R
PWR-2700-DC-R
PWR-3K-DC-Blue
PWR-3K-AC-Red
PWR-3KT-AC -F
PWR-2700-DC-F
PWR-3K-DC-Red
Input power present
Normal Operation
Vin Good
DC Good
Fault
Green
Green
Off
Green
Green
Off
Green
Green
Off
Green
Input power present
Main output off
Vin Good
DC Good
Fault
Green
Off
Off
Green
Off
Off
Green
Off
Off
Blinking Green
Input power present
Power Supply Fault
Vin Good
DC Good
Fault
Green
Off
Blinking Amber
Green
Off
Blinking Amber
Green
Off
Blinking Amber
Blinking Amber,
1 sec on, 1 sec off
No Input Power
Supply installed in chassis
Vin Good
DC Good
Fault
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Input power present
Supply not seated in chassis
Vin Good
DC Good
Fault
Off
Off
Off
Off
Off
Blinking Green
Off
Off
Off
Blinking Amber,
0.5 sec on/off