Print
Overview
1.1 Scope
This guide is intended for properly trained service personnel and technicians who need to install the following Arista Networks Data Center Switches:
DCS-7368X4
Important! Only qualified personnel should install, service, or replace this equipment.

Seul le personnel qualifié doit installer, service, ou remplacer cet équipement.
1.2 Receiving and Inspecting the Equipment
Upon receiving the switch, inspect the shipping boxes and record any external damage. Retain packing materials if you suspect that part of the shipment is damaged; the carrier may need to inspect them.
If the boxes were not damaged in transit, unpack them carefully. Ensure that you do not discard any accessories that may be packaged in the same box as the main unit.
Inspect the packing list and confirm that you received all listed items. Compare the packing list with your purchase order. Appendix B provides a list of components included with the switch.
1.3 Installation Process
The following tasks are required to install and use the switch:
Step 1 Select and prepare the installation site ( Section 2.1).
Step 2 Assemble the installation tools listed in ( Section 2.2).
Step 3 Attach the mounting brackets and install the switch in an equipment rack ( Chapter 3).
Step 4 Connect the switch to the power source and network devices ( Chapter 4 and Chapter 5).
Step 5 Configure the switch ( Chapter 6).
Important! Class 1 Laser Product: This product has provisions to install Class 1 laser transceivers that provides optical coupling to the communication network. Once a Class 1 laser product is installed, the equipment is a Class 1 Laser Product (Appareil à Laser de Classe 1). The customer is responsible for selecting and installing the Class 1 laser transceiver and for insuring that the Class 1 AEL (Allowable Emission Limit) per EN/IEC 6-825, CSA E60825-1, and Code of Federal Regulations 21 CFR 1040 is not exceeded after the laser transceiver have been installed. Do not install laser products whose class rating is greater than 1. Refer to all safety instructions that accompanied the transceiver prior to installation. Only Class 1 laser devices certified for use in the country of installation by the cognizant agency are to be utilized in this product.

Produit Laser de classe 1: Ce produit a des dispositions pour installer des émetteurs-récepteurs de laser de classe 1 qui offre de couplage au réseau de communication optique.Une fois un produit laser de classe 1 est installé, l'équipement est un produit Laser de classe 1 (Appareil à Laser de Classe 1).Le client est responsable pour sélectionner et installer l'émetteur/récepteur de laser de classe 1 et pour assurer que la classe 1 AEL (limite d'émission admissible) par EN/IEC 60825, CSA E60825-1, et Code des règlements fédéraux 21 CFR 1040 ne soit pas dépassée après avoir installé l'émetteur/récepteur de laser. Ne pas installer des appareils à laser dont la cote de classe est supérieure à 1.Voir toutes les consignes de sécurité qui ont accompagné l'émetteur-récepteur avant l'installation. Seuls appareils laser de classe 1 certifiés pour une utilisation dans le pays d’installation par l’organisme compétent doivent être utilisées dans ce produit.
Important! Ultimate disposal of this product must be handled in accordance with all national laws and regulations.

Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien qualifié.
The fabric module requires special handling when removing, inserting, or handling the component. Appendix F provides instructions for handing fabric modules.
1.4 Safety Information
Refer to the Arista Networks document Safety Information and Translated Safety Warnings available at:
https://www.arista.com/en/support/product-documentation
1.5 Obtaining Technical Assistance
Any customer, partner, reseller or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways:
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.. This is the easiest way to create a new service request.
Include a detailed description of the problem and the output of “show tech-support”.
Web: https://www.arista.com/en/support
A support case may be created through the support portal on our website. You may also download the most current software and documentation, as well as view FAQs, Knowledge Base articles, Security Advisories, and Field Notices.
Phone: +1 866-476-0000 or +1 408-547-5502.
Important! No user serviceable parts inside. Refer all servicing to qualified service personnel.

Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien qualifié.
1.6 Specifications
Table 1-1 lists specifications of Arista Data Center modular switches and components covered by this guide.
Table 1-1  7368 Modular Switch and Component Specifications
 
DCS-7368X4
Height
4 RU: 179 mm (7.0 inches)
Width
442 mm (17.4 inches)
Depth
Not including handles and ejectors
559 mm (22.0 inches)
Including handles and ejectors
640 mm (25.2 inches)
Weight
Empty
13.6 kg (30.0 lbs)
Fully Loaded
38.6 kg (85 lbs)
Input Power (per circuit)
AC Power
200 - 240 VAC, 16 A, 50 or 60 Hz
Branch Circuit Protection
AC Power
20 A
Input Power Circuits
2 to 4 circuits
Operating Temperature
Storage Temperature
Operating Altitude
Relative Humidity
0° to 40°C (32° to 104°F)
-40° to 70°C (-40° to 158°F)
0 to 3,000 meters (0 to 10,000 feet)
5 to 90%
Cooling
2000 W maximum
Table 1-2 lists power specifications of modular switch components.
Table 1-2  7368 Modular Switch and Component Power Specifications 
Module Type
Part Number
Power Draw: Typical / Maximum
Supervisor Modules
DCS-7368-SUP-D
DCS-7368-SUP
30 W / 48 W
30 W / 48 W
Linecard Modules
DCS-7368-16C-LC
63 W(1) / 144 W(2)
Switch Card Module (excluding fans)
DCS-7368X4-SC
242 W / 406 W
Fans
 
23 W / 55 W
Power Supplies
PWR-1900-AC
34 W / 57 W
7368 Series System
Full chassis loaded with
1x DCS-7368-SUP-D supervisor
1x DCS-7368X4-SC switch card
8x DCS-7368-16C-LC line cards
5x Fans
2x PWR-1900-AC power supplies
961 W(1) / 1998 W(2)
(1): Excluding optics.
(2): With 4.5 W optics.
 
Chapter PDF
..