- Written by Satish Kumar Selvaraj
- Posted on February 8, 2017
- Updated on March 22, 2017
- 13788 Views
The 7500 and 7280 switch series platforms have previously supported VXLAN bridging, which enables stretching of
- Written by Mihyar Baroudi
- Posted on February 1, 2016
- Updated on January 30, 2017
- 11257 Views
Vxlan routing in multichip systems uses the different modules to do different portions of the packet processing.
- Written by Kaushik Kumar Ram
- Posted on April 16, 2015
- Updated on May 1, 2015
- 9991 Views
MLAG provides Layer2 active/active redundancy. VXLAN is supported over an MLAG setup by having the two switches
- Written by Mihyar Baroudi
- Posted on December 8, 2015
- Updated on October 20, 2017
- 13479 Views
This document describes VXLAN routing with overlay VRFs on the DCS 7050X platforms. The feature allows users to
- Written by Sunil Kumar Mudunuri
- Posted on September 30, 2015
- Updated on February 5, 2022
- 5946 Views
Up until now, the mirroring ACLs on the DCS 7150 series used to support only the security ACL rules. This meant that
- Written by Abhijith Narayan
- Posted on April 24, 2018
- Updated on July 1, 2026
- 9305 Views
This feature makes sure that on a supervisor switchover, VxLAN bridging forwarding state is not affected. In line
- Written by Jeffrey Nelson
- Posted on January 17, 2019
- Updated on December 12, 2025
- 11847 Views
Configuration of VXLAN overlay using EVPN allows for extension of Layer 2 (L2) or Layer 3 (L3) networks across
- Written by Steven Beaudette
- Posted on October 18, 2024
- Updated on October 18, 2024
- 4971 Views
The VXLAN VNI counters feature allows the device to count VXLAN packets received and sent by the device on a per VNI basis. Specifically, it enables the device to count bytes and packets that are encapsulated and decapsulated as they are passing through.
- Written by Pankaj Srivastava
- Posted on September 11, 2023
- Updated on October 17, 2024
- 8121 Views
The document describes the support for policing on one or more VNIs configured on a Vxlan interface. This feature allows dedicated policing of flows on a VNI in both directions which corresponds to incoming traffic from a remote VTEP and outgoing traffic towards a remote VTEP. Policers in the hardware are created with policer profiles attached to VNIs. Policer profiles can be shared across multiple VNIs but policers are dedicated.
- Written by Pankaj Srivastava
- Posted on September 24, 2024
- Updated on September 30, 2024
- 4902 Views
This document describes the support for VNI policing counters on VNIs where the VNI policing feature has been provisioned. Counters for this feature provide information on how many packets are being allowed or dropped for a VNI specific flow due to configured VNI policers. VNI policing counters are supported in both directions which correspond to incoming traffic from a remote VTEP and outgoing traffic towards a remote VTEP. Counters in each direction are configured separately. Both packet and bytes counts are supported.
- Written by Rohit Maurya
- Posted on August 28, 2019
- Updated on March 6, 2026
- 11511 Views
The VXLAN VTEP and VNI counters feature allows the device to count VXLAN packets received and sent by the device on a per VTEP and per VNI basis. Specifically, it enables the device to count bytes and packets that are encapsulated and decapsulated as they are passing through.
- Written by Lavanya Conjeevaram
- Posted on June 29, 2016
- Updated on June 29, 2016
- 11896 Views
The VxLAN VTEP counters feature allows the device to count VxLAN packets received and sent by the device on a per
- Written by Saurabh Kumar
- Posted on April 25, 2025
- Updated on April 25, 2025
- 3343 Views
Pathfinder deployments have restrictions on what devices can form a DPS tunnel between them. All the devices are categorized as either Site or Zone transit or Region transit.
- Written by Vidya Kirupanidhi
- Posted on August 19, 2025
- Updated on August 19, 2025
- 2097 Views
WAN Routing system network comprises multiple routers interconnected using Dynamic Path Selection (DPS) tunnels. Prior to EOS-4.34.2F, the High Availability solution used a static hash to assign flow ownership to an HA peer. This peer was then responsible for Deep Packet Inspection (DPI) and subsequent Advanced Virtualization Technology (AVT) selection based on the DPI results.
- Written by Prachi Modi
- Posted on January 19, 2024
- Updated on January 19, 2024
- 7696 Views
With the 16.0 release, CV-CUE introduces Webhooks that let you send alert notifications in real time to third-party applications. By configuring a webhook, you can share content and notifications with external applications such as Microsoft Teams, ServiceNow, Slack, GSpace, etc.
- Written by Veluchamy Dinakaran
- Posted on September 30, 2015
- Updated on September 30, 2015
- 9570 Views
EOS supports different scheduling policies which dictate the way packets at different transmit queues
- Written by James Nakoda
- Posted on March 3, 2025
- Updated on July 10, 2026
- 4235 Views
WRAS is an EOS extension to automatically manage the layer 1 connectivity of the MetaWatch's WhiteRabbit interface. To install WRAS, use the extension commands as described in the Managing EOS Extensions section of the EOS user guide. Note that the ConfigAgent agent (the agent that hosts Cli) will restart when installing or uninstalling the WRAS extension.
- Written by Dhruba Jyoti Pokhrel
- Posted on December 13, 2024
- Updated on December 13, 2024
- 4623 Views
With the 18.0 release, the Access Point (AP) and CV-CUE Server (previously called Wireless Manager Server or WM Server) connectivity for on-premises and cloud deployments have been updated with additional security and improved security posture of AP-Server communication.
- Written by Prachi Modi
- Posted on February 20, 2023
- Updated on February 21, 2023
- 8924 Views
With the 14.0 release, CV-CUE introduces the following enhancements to WIPS to ensure compliance with Wi-Fi 6 and 6E security requirements:
- Written by Dhruba Jyoti Pokhrel
- Posted on February 2, 2023
- Updated on February 20, 2023
- 9108 Views
With the 13.0.1 release, you can monitor wired hosts that are physically connected to access points (APs) through Ethernet cables. Currently, the W-118 AP and W-318 AP through their additional LAN ports support connecting hosts directly to the AP.
- Written by Dhruba Jyoti Pokhrel
- Posted on December 11, 2022
- Updated on December 12, 2022
- 9363 Views
With the 13.0 release, you can now view switch-related data, which is managed by CVaaS, from CV-CUE. With this capability, CV-CUE provides you full visibility of the edge network from a single pane. You can monitor the network and make informed decisions – for example, when you want to troubleshoot any network issues and find out whether the root cause lies in the wired architecture or the wireless.
- Written by Preyas Hathi
- Posted on June 2, 2022
- Updated on June 2, 2022
- 10171 Views
With the 12.0 release, you can view the details of access switches to which the access points (APs) are connected on the MONITOR > Switch page in CloudVision Cognitive Unified Edge (CV-CUE). The Switch page displays the list of switches to which the APs are connected and the connected Wi-Fi clients.
- Written by Navlok Mishra
- Posted on February 8, 2017
- Updated on September 2, 2025
- 12584 Views
WRED ( Weighted Random Early Detection ) is one of the congestion management techniques. It works at queue level to drop packets randomly after crossing the given queue threshold even before the queue is full. Without WRED, all newly arriving packets get tail dropped once the queue is full, which creates TCP global synchronization issues. WRED helps to avoid TCP global synchronization.
- Written by Alex Reimers
- Posted on February 8, 2017
- Updated on February 16, 2017
- 11005 Views
EOS Yum support is a feature that allows yum repositories to be configured and saved in the running config. This allows
- Written by Mateusz
- Posted on January 8, 2026
- Updated on January 13, 2026
- 957 Views
This guide details how to use Zero Touch Provisioning (ZTP) on Arista switches.
- Written by Keerthana Parthasarathy
- Posted on March 4, 2025
- Updated on March 12, 2026
- 5159 Views
Support for matching of DSCP,ECN,VLAN is available under the QOS class-map configuration on Arista switches.
- Written by Vivek Kumar
- Posted on March 2, 2026
- Updated on March 2, 2026
- 685 Views
The ZTX Session Table Archive feature provides local storage of historical session data on the appliance's SSD, enabling local forensic analysis and troubleshooting. This capability is essential for investigating security incidents, meeting compliance requirements, and analyzing traffic patterns that occurred hours or days in the past.
