- Written by Deepanshu Shukla
- Posted on 8月 21, 2020
- Updated on 1月 12, 2026
- 24353 Views
This feature adds support for “Dynamic Load Balancing (DLB)” on Equal Cost Multi Path (ECMP) groups.
- Written by David Dombai
- Posted on 4月 27, 2026
- Updated on 4月 30, 2026
- 965 Views
Dynamic NAT is a feature which dynamically allocates an IP address to an incoming or outgoing flow. This address will replace source or destination IP for all packets of the flow. The new IP address given to the flow is from a pool of addresses called NAT pool. L4 port can also be replaced by a new one in case of NAPT (Network Address Port Translation). In address only NAT only the IP address is translated. NAPT is not supported in masquerade or overload mode.
- Written by Haomin
- Posted on 4月 27, 2026
- Updated on 4月 30, 2026
- 775 Views
Dynamic NAT Priority feature, which extends the Dynamic NAT feature, allows you to configure the order in which dynamic NAT rules are evaluated by the switch.
- Written by Haomin
- Posted on 10月 10, 2025
- Updated on 10月 10, 2025
- 2167 Views
Dynamic NAT Priority feature, which extends the Dynamic NAT feature, allows you to configure the order in which dynamic NAT rules are evaluated by the switch.
- Written by Ashit Tandon
- Posted on 5月 5, 2025
- Updated on 7月 13, 2026
- 4201 Views
Dynamic Twice NAT is a variant of the dynamic NAT feature where both the source and destination IP can be modified while forwarding a packet. One of the IP addresses will be dynamically assigned, while the other will be statically assigned.
- Written by Niranjan Mahabaleshwar
- Posted on 4月 21, 2026
- Updated on 4月 21, 2026
- 949 Views
enrollz/attestz defines a set of gRPC-based services for TPM enrollment and attestation of network devices. Enrollz: provides the capability to verify the switch’s TPM-rooted identities and rotate switch owner certificates on the device. Attestz: provides the capability to attest the device by inspecting the contents of the different PCR ensuring no malicious tampering.
- Written by Yaonan Liang
- Posted on 9月 24, 2026
- Updated on 9月 24, 2026
- 380 Views
In EVPN deployments, MAC address reachability is ascertained using both (i) MAC only routes, and (ii) MAC-IP routes. If all EVPN peers in the network are guaranteed to advertise a MAC-only route for MACs, then it is redundant to compute MAC reachability based on MAC-IP routes for the same MAC. With higher scale of the number of IPs mapped to the same MAC address, BGP best path work experiences a higher load.
- Written by Brian Neville
- Posted on 8月 8, 2025
- Updated on 10月 23, 2025
- 3023 Views
gNOI (gRPC Network Operations Interface) defines a set of gRPC-based microservices for executing operational commands on network devices.
- Written by Brian Neville
- Posted on 11月 8, 2023
- Updated on 11月 6, 2025
- 11083 Views
gNSI (gRPC Network Security Interface) defines a set of gRPC-based microservices for executing security-related operations on network devices. Some of the RPCs that gNSI exposes are used to rotate security configurations on the switch.
- Written by Prashant Kumar
- Posted on 4月 30, 2025
- Updated on 4月 21, 2026
- 3700 Views
In the realm of network service level agreements (SLAs), a customer often commits to a certain level of service for their clients. This may necessitate limiting bandwidth at the Layer 3 sub-interface level. Currently, egress service policies can achieve bandwidth control, but ingress control lacks a similar mechanism.
- Written by Shan Zhang
- Posted on 6月 29, 2023
- Updated on 4月 20, 2026
- 10138 Views
Generic UDP Encapsulation (GUE) is a general method for encapsulating packets of arbitrary IP or MPLS protocols within a UDP tunnel. While GUE supports an extensible header format with optional data, currently we only support the variant 1 header format, which directly encapsulates the IPv4/IPv6 or MPLS payload without a GUE header.
- Written by Denver Blake
- Posted on 10月 18, 2024
- Updated on 10月 18, 2024
- 5423 Views
This document describes the support for user-defined fields (UDF) acl rules in QoS policy feature. This feature is an extension of QoS policy to allow increased flexibility of the match criteria by using user-defined fields which will help customers control traffic based on other parts of the packet header and payload that is not supported by the other key-fields.
- Written by Girish Dasari
- Posted on 9月 11, 2024
- Updated on 9月 11, 2024
- 5687 Views
IS-IS SR Stateful Switchover (SSO) support allows for a switchover from an active supervisor to a standby supervisor where MPLS traffic remains undisrupted during switchover. This involves reconciliation of all Segment Routing related information in the network using IS-IS Graceful Restart procedures. And also installing the same in forwarding hardware in a manner that does not disrupt the ongoing traffic.
- Written by Nilesh Unhale
- Posted on 8月 12, 2025
- Updated on 9月 2, 2026
- 2733 Views
MIBs are used in SNMP (Simple Network Management Protocol) to monitor and manage network devices. IS-IS MIB provides structured information to track IS-IS protocol performance, routing table status, and link-state information.
- Written by Alok Kumar
- Posted on 11月 29, 2023
- Updated on 7月 7, 2025
- 9234 Views
This feature provides a CLI command showing the list of mac addresses that could not be learned due to hash collision in the hardware table. A hash collision occurs when two or more distinct pieces of data map to the same entry ( or slot ) in the hardware table. It can happen when the hash function used to calculate the index for a given mac address results in the already occupied index, resulting in the failure of inserting the later mac address to the hardware table.
- Written by Venkata Kishore Madhbhaktula
- Posted on 12月 17, 2019
- Updated on 5月 23, 2025
- 13806 Views
Enforces the MTU for Layer 3 packets on 7280R3/7500R3/7800R3 switches. The MTU can be set on any SVI and the MTU of that specific SVI is enforced when the packets egress out of a trunk port. This behavior is not supported on 7280E/R/R2 and 7500E/R/R2 line cards.
- Written by Brian
- Posted on 4月 21, 2026
- Updated on 4月 21, 2026
- 688 Views
The latency monitor feature allows measurement and display of end-to-end packet latency as seen at egress interfaces. Packet latency is measured from switch ingress to switch egress, but does not include latency due to front-panel PHYs.
- Written by Brian Schuette
- Posted on 4月 30, 2025
- Updated on 11月 11, 2026
- 5393 Views
Linear pluggable optics (LPO) represent a significant advancement in transceiver technology. These modules are designed to reduce costs, power consumption, and latency compared to traditional Digital Signal Processing (DSP) based transceivers.
- Written by Eudean Sun
- Posted on 4月 30, 2025
- Updated on 4月 30, 2025
- 3735 Views
The Linux audit system provides the ability to record security events on the switch. Audit rules must be configured and enabled at the CLI. Audit rules can be configured in different groups to assist with organization and maintenance.
- Written by Hongda Huang
- Posted on 4月 25, 2025
- Updated on 4月 25, 2025
- 3628 Views
The Lowest Load feature uses load as a key metric for selecting the best path. When this metric is prioritized, routers will choose the path with the lowest load as the best option.
- Written by Vishrant Vasavada
- Posted on 4月 24, 2025
- Updated on 4月 24, 2025
- 3802 Views
DMF 8.7.0 provides support for Management Redundancy on an Extensible Operating System (EOS) Fixed System Chassis. It provides a method to enable redundant active/active connectivity on the management IP address for a Danz Monitoring Fabric (DMF) switch in a fixed system chassis using an out-of-band management port and a front-panel port on the switch.
- Written by Christopher Brown
- Posted on 12月 16, 2020
- Updated on 3月 7, 2025
- 11670 Views
ARP and IPv6 Neighbor Discovery use a neighbor cache to store neighbor address resolutions. The capacity of the neighbor cache is determined by the resources and capabilities of the device platform. The neighbor cache capacity feature adds a means to specify a per-interface capacity for the neighbor cache. A neighboring device, through misconfiguration or maliciousness, can unfairly use a large number of address resolutions. This feature can help to mitigate this over-utilization.
- Written by Christopher Brown
- Posted on 3月 17, 2026
- Updated on 3月 17, 2026
- 1057 Views
ARP and IPv6 Neighbor Discovery use a neighbor cache to store neighbor address resolutions. The cache maintains the resolutions for an interval of time after which a refresh process begins. During the refresh process, a number of ARP requests or IPv6 ND Neighbor Solicitations are sent to the neighbor until the neighbor either responds with an ARP reply or IPv6 ND Neighbor Advertisement.
- Written by Yuanzhi Gao
- Posted on 10月 14, 2019
- Updated on 1月 5, 2026
- 10023 Views
Nexthop Group tunnels are a tunneling abstraction in EOS. A nexthop group tunnel consists of a tunnel endpoint (IP prefix) and a nexthop group name representing the underlying nexthop group that forwards the traffic. If the underlying nexthop group is not configured, the tunnel endpoint will be unreachable until the given nexthop group is configured.
- Written by Matthew Carrington-Fair
- Posted on 8月 12, 2025
- Updated on 8月 12, 2025
- 2799 Views
This feature allows configuring backup nexthop group entries to be used if their corresponding primary entries are unable to forward traffic due to being unresolved or with outgoing interfaces that are marked as down. By default, any configured backup entries will not be activated to forward traffic until all primary nexthop group entries are unavailable. Backup nexthop group entries are a tool used to achieve fast failover when forwarding traffic via nexthop groups.
- Written by Kartic Bhargav
- Posted on 10月 1, 2026
- Updated on 10月 1, 2026
- 268 Views
This feature adds support to configure the following QoS OpenConfig models via gNMI maximum queue length of a queue on a port within a given polling interval, average queue length of a queue on a port within a given polling interval
- Written by Sulyab Thottungal Valapu
- Posted on 10月 29, 2020
- Updated on 10月 17, 2024
- 12091 Views
This document describes the OSPFv2 and OSPFv3 feature that allows enabling or disabling the inclusion of LSAs having “Down” (DN) bit set in SPF calculations. The DN Bit is a loop prevention mechanism implemented when OSPF is used as CE - PE IGP protocol.
- Written by Manjula Gopalakrishnan
- Posted on 7月 13, 2018
- Updated on 7月 13, 2018
- 11421 Views
This feature enables the user to configure PBR policy on an interface in any VRF, to match and forward incoming packets
- Written by Mingchao Lian
- Posted on 6月 26, 2026
- Updated on 6月 26, 2026
- 575 Views
In order to support PIM/IPv4 multicast routing on EOS switches with Broadcom Tomahawk5 ASICs, multicast support using ALPM tables is required. This works in both 3-level Algorithmic Longest Prefix Match (ALPM) capabilities and 2-level ALPM.
- Written by Mingchao Lian
- Posted on 9月 11, 2024
- Updated on 6月 26, 2026
- 5922 Views
In order to support PIM/IPv4 multicast routing on EOS switches with Broadcom Tomahawk4 ASICs, multicast support using ALPM is required. This works in both 3-level Algorithmic Longest Prefix Match (ALPM) capabilities and 2-level ALPM.
- Written by Mehul Mistry
- Posted on 8月 12, 2025
- Updated on 3月 17, 2026
- 3253 Views
Port isolation is a feature that segregates the ports in a VLAN broadcast domain into isolated and non-isolated ports and facilitates blocking traffic between ports marked as isolated. Isolated ports in a VLAN are the ports that cannot send/receive traffic from other isolated ports in the same VLAN. However, they should still be able to communicate with non-isolated ports
- Written by Basil Saji
- Posted on 11月 9, 2020
- Updated on 7月 13, 2026
- 19000 Views
Private VLAN is a feature that segregates a regular VLAN broadcast domain while maintaining all ports in the same IP subnet. There are three types of VLAN within a private VLAN
- Written by Venkata Vyshnav Lagisetty
- Posted on 3月 1, 2024
- Updated on 11月 3, 2025
- 2220 Views
The feature adds support for redirecting traffic matching on traffic policy rules applied to an egress interface to a specified next-hop or next-hop group. This feature requires the packet to be recirculated a second time through the packet forwarding pipeline to get its configured single or multiple next-hops to be resolved. This is achieved by configuring traffic-policy with redirect interface action applied on egress interface in conjunction with ingress redirect next-hop action applied on the recirculation interface.
- Written by Gaofeng Yue
- Posted on 12月 20, 2021
- Updated on 7月 21, 2026
- 13163 Views
Currently EOS supports redistribution into BGP at the global ( instance ) level. Also EOS supports redistribution in BGP at Address Family Identifier/Subsequent Address Family Identifier(AFI/SAFI) level to some extent. But the current redistribution mechanism is not flexible and does not provide full control at AFI/SAFI level ( some redistribution protocols are only supported at global level, or at some AFI/SAFI level ). This feature will support redistribution at AFI/SAFI level as well as at the global level. This will simplify the configuration requirements and supportability for complex and granular configurations when subsequent address family configurations co-exist. This will also give more control at AFI/SAFI level ( for example, route-map/rcf can be configured at AFI/SAFI level while they are not configured at global level ). This feature only works in multi-agent routing model.
- Written by Praneel Jhunjhunwala
- Posted on 1月 3, 2025
- Updated on 1月 3, 2025
- 4711 Views
A remark is a user specified comment that is written within an IP prefix-list. Remarks allow documentation to be added directly into the configuration of an IP prefix-list. Both IPv4 and IPv6 prefix-lists are supported.
- Written by Fei Rao
- Posted on 12月 20, 2024
- Updated on 12月 20, 2024
- 4937 Views
There are two types of reload on a switch running EOS, normal reload and Smart System Upgrade (SSU). Scheduled normal reload is supported via ‘reload in’ command, to perform a normal reload after a specified delay. It asks for saving unsaved configuration changes and confirmation in order to schedule the reload. Scheduled SSU is supported via ‘reload fast-boot in’ command. However, after scheduling an SSU reload, if there are unsaved configuration changes, or saved configuration changes which block an SSU reload, the scheduled reload will be aborted at scheduled time.
- Written by Ayush
- Posted on 9月 5, 2025
- Updated on 9月 5, 2025
- 2439 Views
User Defined Fields (UDFs) are access-list (ACL) filters that consist of an offset into a packet and a pattern to match at the given offset. It can be used to match non-standard fields in a packet that don’t have existing well-defined filter criteria. An example of a non-standard field is bytes at an arbitrary offset within a UDP payload.
- Written by Nikhil Satish Pai
- Posted on 4月 21, 2026
- Updated on 4月 21, 2026
- 744 Views
The feature allows setting the Forwarding Address field for OSPFv2 Type 5 External LSAs. By default, OSPFv2 populates the FA based on the next-hop value of the redistributed source route, regardless of the outgoing interface type.
- Written by Matthieu Simon
- Posted on 9月 19, 2025
- Updated on 9月 19, 2025
- 2426 Views
This document describes a new feature of Arista Analytics that can process sFlow® records containing IP packets encapsulated in additional protocol headers.
- Written by Joanna Shao
- Posted on 3月 12, 2026
- Updated on 3月 13, 2026
- 1038 Views
This feature adds support for configuring an interface as a TX mirror source and a source for egress sFlow at the same time. For more information about mirroring and egress sFlow see the Resources section below.
- Written by Charlotte Fedderly
- Posted on 8月 25, 2020
- Updated on 3月 26, 2025
- 15511 Views
This feature adds support for a selected set of configured interfaces to collect egress flow samples. Egress sFlow can be configured on Ethernet and Port-Channel interfaces, and on subinterfaces on select platforms. Hardware acceleration is not currently supported for egress sFlow and all sample processing is performed in software.
- Written by Ghanashyam
- Posted on 9月 23, 2026
- Updated on 9月 25, 2026
- 419 Views
Segment Routing over IPv6 (SRv6) Micro Segment (uSID) is a high-efficiency architecture that drastically reduces packet header overhead by compressing and packing multiple routing instructions into a single 128-bit IPv6 address. To ensure robust operational visibility, this feature integrates native endpoint counters that track real-time packet and byte volumes for every endpoint operation (such as uN processing), providing network operators with granular telemetry for streamlined debuggability, path verification, and traffic analysis.
- Written by Girish Dasari
- Posted on 7月 6, 2026
- Updated on 9月 28, 2026
- 1008 Views
SRv6 is the segment routing using IPv6 Data plane. The segment ID is encoded as an IPv6 address. The Micro-Segment extension to SRv6 has representation of SIDs to enable compressing multiple of them into a single IPv6 address.
- Written by Ram Prasad
- Posted on 3月 12, 2026
- Updated on 9月 25, 2026
- 1632 Views
In Segment Routing, Adjacency Segment (Adj-SID) directs a node to forward the packet over a specific link or a set of links to the remote node. This feature adds support for statically configured SRv6 Adj-SIDs using micro-SIDs, also referred to as uA. This feature builds on the base SRv6 support described in SRv6 uN Support TOI.
- Written by Jingyao Li
- Posted on 7月 10, 2025
- Updated on 7月 10, 2025
- 3052 Views
This feature adds the support for tracking the number of syslog messages sent to the server and the number of syslog messages received on the server, along with other log forwarding action statistics, continuously within the existing syslog logging mechanism.
- Written by Bruno
- Posted on 7月 17, 2025
- Updated on 7月 17, 2025
- 2839 Views
This feature terminates GTP packets arriving on a tap port of a TapAgg switch by stripping the GTP header. The decapsulated (inner) packets then proceed through the normal TapAgg path. This functionality allows a GTPv1 tunnel to transmit tapped traffic to the TapAgg switch over an L3 network, significantly extending the available use cases for TapAgg.
- Written by Ioana Costea
- Posted on 10月 24, 2024
- Updated on 10月 24, 2024
- 4937 Views
The S-BFD hold down timer feature enables delaying the steering of traffic to a previously preferred SR-TE Down path that came back Up. This delay period is configurable. Using this functionality allows time for the path to stabilize (by avoiding potential further path flaps) and allows the user to debug and diagnose the failure state.
- Written by Dhruba Jyoti Pokhrel
- Posted on 5月 28, 2026
- Updated on 5月 28, 2026
- 674 Views
CV-CUE supports three NTP servers for synchronizing APs with them. Providing the IP address or hostname of at least one server, Server 1, is mandatory. For the other two servers, the sequence of operation is inconsequential. You can add the third server (Server 3) and leave the second server (Server 2) empty.
- Written by Sandeep Kopuri
- Posted on 10月 7, 2019
- Updated on 11月 7, 2025
- 19956 Views
Topology Independent Fast Reroute, or TI-LFA, uses IS-IS SR to build loop-free alternate paths along the post-convergence path. These loop-free alternates provide fast convergence.
- Written by John Weismiller
- Posted on 8月 12, 2025
- Updated on 10月 21, 2025
- 4004 Views
The Traffic Generator is an EOS feature that allows network traffic generation on Arista switches. It provides a simple and effective way to create high-speed traffic for testing and validation purposes. It can send a continuous stream of custom-defined packets at full speed to one or more destination interfaces
