This feature expands Multi Domain EVPN VXLAN to support an Anycast Gateway model as the mechanism for gateway

EOS 4.15.0F added support for a CLI knob to determine whether the L3 forwarding agent (responsible for programming FECs and routes into hardware) would react to BFD status events for an interface to update next-hop programming for FECs programmed in hardware. This required two events, one for the BFD session to transition to an “Up” status and a subsequent transition to a “Down” status. This is identical to how various protocols in EOS (i.e. BGP, IS-IS) leverage BFD for faster down detection, and is useful to allow the L3 forwarding agent to preemptively remove next hops that would later be deprogrammed due to protocol session status state.

Arista’s DCS-7130LBR series of switches (https://www.arista.com/en/support/toi/eos-4-30-2f/15900-dcs-7130lbr-48s6qd-series) are capable of supporting SwitchApp, which is an FPGA-based L2/L3 switch. However, as the switch would then contain two switch ASICs (one traditional switch ASIC, and one FPGA-based switch) physically upon loading the SwitchApp application, there are certain limitations and nuances along with its usage. This document intends to explain some of the details.

This feature enables exchanging IPv4 NLRI using MP BGP over an IPv6 TCP connection.  Additionally, this feature

Network Administrators can enable identity validation to ensure that Access Points (APs) establish secure RadSec and Rsyslog connections only with verified and trusted servers. When enabled, the AP verifies the server's identity during the TLS handshake for RadSec and Rsyslog communication by matching the server's hostname against the Subject Alternative Name (SAN) or Common Name (CN) fields in the server’s certificate. If both the fields are present, then SAN takes priority over CN. CN validation happens only if SAN is not provided.

Virtual Private LAN Service (VPLS) can be used when one wishes to connect several LANs dispersed across a packet switched network. VPLS can allow the dispersed LANs to act like a single bridged LAN by providing a service to connect the LANs. The service will appear like an Ethernet LAN (in almost all regards). VPLS achieves this by creating a mesh of pseudowires that connect the dispersed LANs, while also processing the traffic that moves through the pseudowires in a similar way to how a L2 service would. For example, MAC address learning, flooding and forwarding functions are applied to the pseudowire traffic in a VPLS. This allows  VPLS to mimic the functionality of an any-to-any L2 service when connecting dispersed LANs.

The Arista Service Node (SN) provides specialized packet processing within the DANZ Monitoring Fabric (DMF), which is not easily accomplished within the CPU on a switch.  The SN provides a packet processing pipeline tied to a physical interface, reading packets and writing results from the same interface.

This article describes the support of a VLAN filter for IP, IPV6 and MAC ACLs on the ingress ports. The users will be able to filter the packets by specifying a VLAN id in the ACL rule. VLAN id specified in the ACL rule is internal broadcast domain VLAN id. 

The Tap Aggregation Traffic Steering feature provides support for filtering data streams received on tap ports and directing flows to tool ports based on user-configurable match rules, using either class maps and policy maps or traffic policies.

 

This document describes LLDP’s VLAN Name TLV. It is defined in IEEE 802.1Q standard (802.1Q - D.2.3) and contains a list of VLAN names that the port is assigned to. This TLV is optional and it is disabled by default in Arista switches.

This feature is available in the VLAN configuration mode. When a switch receives a packet with unknown destination MAC address on a VLAN, L2 miss happens. The current behavior for L2 miss packets is to flood the packet on all ports of the VLAN. In certain cases, there may be a preference to drop or log L2 miss packets instead of flooding them across the VLAN.

VLAN Pooling is a list of VLAN IDs defined by the Network Administrator. The Access Point (AP) distributes the VLAN IDs from this pool of VLAN to the clients connecting to the SSID.VLAN Pooling offers better scalability and optimized load-balancing of traffic.

The VLAN mapping or translation feature provides the ability to map an arbitrary VLAN tag to a particular bridging VLAN on the switch. This mapping can be either bidirectional or applied only in one direction (incoming/outgoing). The mapping is applied on a trunk port and multiple mappings can co-exist under each trunk port.

With a static configured import and export route-target for a given vlan-aware-bundle, all its VLAN members share the same route-target value. For example, EVPN uses the same route-target in the Type 2 EVPN route advertisements for hosts residing in two different VLAN of the same bundle.

As of EOS 4.15.2F, VM Tracer adds support for VMware NSX V. This includes supporting NSX V specific features, improved

Prior to EOS 4.24.1F, per-destination steering into an SR Policy was only supported for IP unicast BGP routes in the default VRF.

VRF redirection often requires matching packets’ source addresses against one or more sets of IP prefixes.  This can become difficult to manage when the prefix sets need to be consistently maintained on several devices and either change too frequently or are very large.  When the prefixes for the prefix sets are learned by BGP, this feature provides an alternative to maintaining unwieldy sets of statically configured IP prefixes.

This document describes how to use the new feature, VRRP IPv6 using VRRP IPv4 MAC prefixes. RFC 5798 defines a specific

Traceroute and tracert are widely available diagnostic command-line interface commands for displaying possible routes (paths) and transit delays of packets across an Internet Protocol (IP) network. This enhancement applies to IPv4 and IPv6 overlay. The VTEP overlay ICMPs for “time-to-live expired” (aka TTL-expired) are sourced with the VTEP IP which results in the traceroute output to display the VTEP IPs on the overlay packet’s path from source to destination.

This feature allows the VRRP MAC and IP to be advertised via EVPN MAC-IP routes when VRRP is configured on the VTEP.

When a frame gets bridged from an edge port to a VXLAN core port, it is necessary to encode the QOS fields in the outer

This feature allows an operator to configure a centralized routing topology with an IPv6 VXLAN underlay. This is useful for customers who want to use an anycast (VARP) gateway for routing over an IPv6 control plane. VARP allows multiple switches to simultaneously route packets from a common IP address in an active-active router configuration. Each switch is configured with the virtual IP address and a common virtual MAC address.

This feature makes IGMP Snooping aware of VXLAN endpoints. Without this feature, multicast data traffic is flooded to all the VXLAN endpoints in case of a VXLAN VLAN. This increases the underlay network utilization. It is desirable to forward multicast traffic to only those VXLAN endpoints that are attached to receivers. To identify interested VXLAN endpoints, this feature snoops IGMP reports that are coming from the remote VXLAN endpoints. Note: EVPN control plane is not required when using this feature.

The VXLAN Control Service (VCS) provides a mechanism by which hardware VTEPs share states between each other in order

This feature allows selecting Differentiated Services Code Point (DSCP) and Traffic Class (TC) values for packets at VTEPs along VXLAN encapsulation and decapsulation directions respectively. DSCP is a field in IP Header and TC is a tag associated with a packet within the switch, both influence the Quality of Service the packet receives. This feature can be enabled via configuration as explained later in this document.

Hardware Head End Replication (HW HER) optimizes flooding of inter VTEP broadcast, unknown unicast and broadcast

In EOS 4.18.0F, VXLAN direct routing was introduced on the 7500R and 7280E/R series platforms. VXLAN routing

The VxLAN MAC drop feature directs all VxLAN MAC addresses to a drop destination, causing the switch to drop all egress VxLAN bridging traffic, effectively disabling VxLAN bridging on the switch. VxLAN routing is unaffected. In some VxLAN routing-only deployments, bridging tunnels are unused yet still consume hardware resources. This feature frees the tunnel hardware resources used for VxLAN bridging, which can then be allocated for VxLAN routing. This in turn allows the switch to support more remote VTEPs. Typical use cases include centralized routing gateways or spines in EVPN-VxLAN fabrics, and VESPA (Virtual Ethernet Segment with Proxy ARP) gateways in wireless campus deployments.

VXLAN multicast decapsulation enables VTEPs that only support HER (Head End Replication) to terminate multicast

VXLAN is a Layer 2 technology that helps you to create a virtual Layer 2 network (overlay network) on top of a physical

VXLAN ARP and IPv6 Neighbor Discovery (NDP) packet headend replication capability via VxlanSwFwd matches the COPP rate limit for these packets for the supported platforms regardless of the size of the VXLAN flood VTEP list. However, there still remains a case where the handling capacity is limited by CPU: the handling of ARP broadcast and NS multicast that result from Glean traffic (post routing).

With the 12.0 release, CloudVision Cognitive Unified Edge (CV-CUE) supports a new tunnel type —  VXLAN over IPSec. You need to specify a tunnel type when you create an SSID.

VxLAN bridging enables stretching Layer 2 domains across a Layer 3 cloud. VxLAN routing provides the capability to

The 7500 and 7280 switch series platforms have previously supported VXLAN bridging, which enables stretching of

Vxlan routing in multichip systems uses the different modules to do different portions of the packet processing.

MLAG provides Layer2 active/active redundancy. VXLAN is supported over an MLAG setup by having the two switches

This document describes VXLAN routing with overlay VRFs on the DCS 7050X platforms. The feature allows users to

Up until now, the mirroring ACLs on the DCS 7150 series used to support only the security ACL rules. This meant that

This feature makes sure that on a supervisor switchover, VxLAN bridging forwarding state is not affected. In line

Configuration of VXLAN overlay using EVPN allows for extension of Layer 2 (L2) or Layer 3 (L3) networks across

Previously, when both “ipv6 nd proxy prefix connected” and VXLAN is configured for a VLAN interface, and the router received a Neighbor solicitation (NS) with an IPv6 address within the connected prefix of the router, the router replied with the interface physical (or virtual-router if VARP is configured) mac address as long as the NS is received on a local (front-panel) port. This feature extends the behavior to also include the NS received from the VXLAN tunnel.

This feature is used to add VXLAN support for local-proxy-arp, Previously, when both “ip local-proxy-arp” and VXLAN is configured for a VLAN interface, and the router received an ARP request with an IP address within the same subnet as the router, the router replied with the interface physical (or virtual-router if VARP is configured) mac address for requests that are received on a local (front-panel) port. This feature extends the behavior to include the VXLAN tunneled ARP requests.

The VXLAN VNI counters feature allows the device to count VXLAN packets received and sent by the device on a per VNI basis. Specifically, it enables the device to count bytes and packets that are encapsulated and decapsulated as they are passing through.

The document describes the support for policing on one or more VNIs configured on a Vxlan interface. This feature allows dedicated policing of flows on a VNI in both directions which corresponds to incoming traffic from a remote VTEP and outgoing traffic towards a remote VTEP. Policers in the hardware are created with policer profiles attached to VNIs. Policer profiles can be shared across multiple VNIs but policers are dedicated.

This document describes the support for VNI policing counters on VNIs where the VNI policing feature has been provisioned. Counters for this feature provide information on how many packets are being allowed or dropped for a VNI specific flow due to configured VNI policers. VNI policing counters are supported in both directions which correspond to incoming traffic from a remote VTEP and outgoing traffic towards a remote VTEP. Counters in each direction are configured separately. Both packet and bytes counts are supported.

The VXLAN VTEP and VNI counters feature allows the device to count VXLAN packets received and sent by the device on a per VTEP and per VNI basis. Specifically, it enables the device to count bytes and packets that are encapsulated and decapsulated as they are passing through.

The VxLAN VTEP counters feature allows the device to count VxLAN packets received and sent by the device on a per

Pathfinder deployments have restrictions on what devices can form a DPS tunnel between them. All the devices are categorized as either Site or Zone transit or Region transit.

WAN Routing system network comprises multiple routers interconnected using Dynamic Path Selection (DPS) tunnels. Prior to EOS-4.34.2F, the High Availability solution used a static hash to assign flow ownership to an HA peer. This peer was then responsible for Deep Packet Inspection (DPI) and subsequent Advanced Virtualization Technology (AVT) selection based on the DPI results.

With the 16.0 release, CV-CUE introduces Webhooks that let you send alert notifications in real time to third-party applications. By configuring a webhook, you can share content and notifications with external applications such as Microsoft Teams, ServiceNow, Slack, GSpace, etc.