Overview
Scope
This guide is for properly trained service personnel and technicians who need to install the Arista DCA-CV-100 CloudVision appliance.
Receiving and Inspecting the Equipment
Upon receiving the appliance, inspect the shipping boxes and record any external damage. Retain packing materials if you suspect that part of the shipment is damaged; the carrier may need to inspect them.
If the boxes were not damaged in transit, unpack them carefully. Ensure that you do not discard any accessories that may be packaged in the same box as the main unit.
Inspect the packing list and confirm that you received all listed items. Compare the packing list with your purchase order. The Appendix provides a list of components included with the appliance.
Installation Process
The following tasks are required to install and use the appliance:
Safety Information
Refer to the Arista Networks document Safety Information and Translated Safety Warnings at https://www.arista.com/en/support/product-documentation.
Obtaining Technical Assistance
- Email: 이 이메일 주소가 스팸봇으로부터 보호됩니다. 확인하려면 자바스크립트 활성화가 필요합니다..
This is the easiest way to create a new service request.
- Web: https://www.arista.com/en/support/customer-support.
You can create a support case through the support portal on our website. You may also download the most current software and documentation, and view FAQs, Knowledge Base articles, Security Advisories, and Field Notices.
- Phone: 866-476-0000 or 408-547-5502.
Supplemental Documentation
Refer to the Arista EOS User Guide or additional configuration requirements at https://www.arista.com/en/support/product-documentation.
specifications
Table 1 - Appliance specifications lists the specifications of the Arista CloudVision appliance.
| Size (W x H x D) | Height: 42.8 mm (1.68 inch)
Width:
Depth (excludes bezel): 607.0 mm (23.89 inch) |
| Weight | Weight (maximum): 19.9 kg (43.87 lb)
Weight (empty): 16.73 kg (36.88 lb) |
| Operating Temperature | Continuous operation (for altitude less than 950 m or 3117 ft): 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Maximum temperature gradient (operating and storage): 20°C/h (36°F/h) |
| Storage Temperature | –40°C to 65°C (–40°F to 149°F) |
| Operating Altitude | 3048 m (10,000 ft). |
| Relative Humidity | 10% to 80%
Relative Humidity with 29°C (84.2°F) maximum dew point. |
| Power Input (AC Power) | 550 W |
| Power Draw (Typical / Maximum) | 550 W (Platinum) AC (100–240 V, 50/60 Hz, 7.4 A-3.7 A) |