Install Partner Gateway
This document discusses the steps needed to install and deploy VeloCloud SD-WAN Gateway as a Partner Gateway. It also discusses how to configure the VRF/VLAN and BGP configuration necessary on the SASE Orchestrator on the Partner Gateway.
Installation Overview
This section provides an overview of VeloCloud Partner Gateway installation.
About Partner Gateways
- One interface is facing the private and/or public WAN network and is dedicated to receiving VCMP encapsulated traffic from the remote edges, as well as standard IPsec traffic from Non SD-WAN Destinations.
- Another interface is facing the datacenter and provides access to resources or networks attached to a PE router, which the Partner Gateway is connected to. The PE router typically affords access to shared managed services that are extended to the branches, or access to a private (MPLS / IP-VPN) core network in which individual customers are separated.
The following distributions are provided:
| Provided | Description | Example |
|---|---|---|
| Arista | Gateway OVA package. | velocloud-vcg-X.X.X-GA.ova |
| KVM | Gateway qcow2 disk image. | velocloud-vcg-X.X.X-GA.qcow2 |
Minimum Hypervisor Hardware Requirements
The SD-WAN Gateway runs on a standard hypervisor (KVM or VMware ESXi).
Minimum Server Requirements
- CPU: Intel XEON (10 cores minimum to run a single 8-core gateway VM) with minimum clock speed of 2.0 Ghz is required to achieve maximum performance.
- ESXi vmxnet3 network scheduling functions must have 2 cores reserved per Gateway virtual machine (VM), regardless of the number of cores assigned to the Gateway.
- Example: Assume there is a 24-core server running ESXi+vmxnet3. You can deploy 2- (8 core) Gateways. i.e. 2 gateways multiplied by 8 cores requires 16 cores reserved for gateway application and leaves 8 free cores. By using the formula above, in order to support these two Gateways running at peak performance scale the ESXi/vmxnet3 system requires an additional 4 cores (two cores for each of the two Gateways deployed). That is a total of 20 cores required to run 2 gateways on a 24 core system.
Note: When using SR-IOV, the network scheduling function is offloaded to the pNIC to achieve higher performance. However, the hypervisor must still perform other scheduling functions like CPU, memory, NUMA allocation management. It is required to always keep two free cores for hypervisor usage.
- Example: Assume there is a 24-core server running ESXi+vmxnet3. You can deploy 2- (8 core) Gateways. i.e. 2 gateways multiplied by 8 cores requires 16 cores reserved for gateway application and leaves 8 free cores. By using the formula above, in order to support these two Gateways running at peak performance scale the ESXi/vmxnet3 system requires an additional 4 cores (two cores for each of the two Gateways deployed). That is a total of 20 cores required to run 2 gateways on a 24 core system.
- ESXi vmxnet3 network scheduling functions must have 2 cores reserved per Gateway virtual machine (VM), regardless of the number of cores assigned to the Gateway.
- The CPU must support and activate the following instruction sets: AES-NI, SSSE3, SSE4, RDTSC, RDSEED, RDRAND, AVX/AVX2/AVX512.
- A minimum of 4GB free RAM must be available to the server system aside from the memory assigned to the PGW VMs. One Gateway VM requires 16GB RAM, or 32GB RAM if certificate-based authentication is activated.
- Minimum of 150GB magnetic or SSD based, persistent disk volume (One Gateway VM requires 64GB or 96GB Disk Volume, if certificate-based authentication is activated).
- Minimum required IOPS performance: 200 IOPS.
- Minimum 1x10Ge network interface ports and 2 ports is preferred when enabling the Gateway partner hand-off interface (1Ge NICs are supported, but will bottleneck performance). The physical NIC cards supporting SR-IOV are Intel 82599/82599ES and Intel X710/XL710 chopstick. (See the ‘Enable SR-IOV’ guide).
Note: SR-IOV does not support NIC bonding. For redundant uplinks, use ESXi vSwitch.
- VeloCloud Gateway is a data-plane intensive workload that requires dedicated CPU cycles to ensure optimal performance and reliability. Meeting these defined settings are required to ensure the Gateway VM is not oversubscribing the underlying hardware and causing actions that can destabilize the Gateway service (e.g. NUMA boundary crossing, memory, and/or vCPU oversubscription).
- Ensure that the SD-WAN Partner Gateway VM and the resources such as network interfaces, memory, physical CPUs used to support it fit within a single NUMA node.
Note: Configure the host BIOS settings as follows:
- Hyper-threading- Turned off
- Power Savings- Turned off
- CPU Turbo- Enabled
- AES-NI- Enabled
- NUMA Node Interleaving- Turned off
- Use ESXi host version: ESXi-6.7.0-14320388-standard or above
- Upgrade VM compatibility should be set before starting the Gateway SD-WAN Gateway instance
| NIC Chipset | Hardware | Specification |
|---|---|---|
| Intel 82599/82599ES | HP DL380G9 | http://www.hp.com/hpinfo/newsroom/press_kits/2014/ComputeEra/HP_ProLiantDL380_DataSheet.pdf |
| Intel X710/XL710 | Dell PowerEdge R640 | https://www.dell.com/en-us/work/shop/povw/poweredge-r640
|
| Intel X710/XL710 | Supermicro SYS-6018U-TRTP+ | https://www.supermicro.com/en/products/system/1U/6018/SYS-6018U-TRTP_.cfm
|
| Intel E810-CQDA2 | Dell PowerEdge R640 | https://www.dell.com/en-us/work/shop/povw/poweredge-r640
|
| Hardware Manufacturer | Firmware Version | Host Driver for Ubuntu 20.04.6 | Host Driver for Ubuntu 22.04.2 | Host Driver for ESXi 7.0U3 | Host Driver for ESXi 8.0U1a |
|---|---|---|---|---|---|
| Dual Port Intel Corporation Ethernet Controller XL710 for 40GbE QSFP+ | 7.10 | 2.20.12 | 2.20.12 | 1.11.2.5 and 1.11.3.5 | 1.11.2.5 and 1.11.3.5 |
| Dual Port Intel Corporation Ethernet Controller X710 for 10GbE SFP+ | 7.10 | 2.20.12 | 2.20.12 | 1.11.2.5 and 1.11.3.5 | 1.11.2.5 and 1.11.3.5 |
| Quad Port Intel Corporation Ethernet Controller X710 for 10GbE SFP+ | 7.10 | 2.20.12 | 2.20.12 | 1.11.2.5 and 1.11.3.5 | 1.11.2.5 and 1.11.3.5 |
| Dell rNDC X710/350 card | nvm 7.10 and FW 19.0.12 | 2.20.12 | 2.20.12 | 1.11.2.5 and 1.11.3.5 | 1.11.2.5 and 1.11.3.5 |
| Dual Port Intel Corporation Ethernet Controller E810-CQDA2 for 100GbE QSFP | 4.20 | ICE 1.11.14 | ICE 1.11.14 | Not supported yet | Not supported yet |
| Hypervisor | Supported Versions |
|---|---|
| VMware |
|
| KVM |
|
SD-WAN Gateway Virtual Machine (VM) Specification
- If using VMware ESXi:
- Latency Sensitivity must be set to 'High'.
- Procedure (Adjust Latency Sensitivity)
- Browse to the virtual machine in the vSphere Client.
- To find a virtual machine, select a data center, folder, cluster, resource pool, or host.
- Select the VMs tab.
- Right-click the virtual machine, then select Edit Settings.
- Select VM Options, then select Advanced.
- Select a setting from the Latency Sensitivity drop-down menu.
- Select OK.
- Browse to the virtual machine in the vSphere Client.
- CPU reservation set to 100%.
- CPU shares set to high.
- CPU Limit must be set to Unlimited.
- 8 vCPUs (4vCPUs are supported but expect lower performance).
Important: All vCPU cores should be mapped to the same socket with the Cores per Socket parameter set to either 8 with 8 vCPUs, or 4 where 4 vCPUs are used.Note: Hyper-threading must be deactivated to achieve maximum performance.
- Procedure for Allocate CPU Resources:
- Select Virtual Machines in the Arista Host Client inventory.
- Right-click a virtual machine from the list and select Edit settings from the pop-up menu.
- On the Virtual Hardware tab, expand CPU, and allocate CPU capacity for the virtual machine.
Table 5. Virtual Machine Option Descriptions Option Description Reservation Guaranteed CPU allocation for this virtual machine. Limit Upper limit for this virtual machine’s CPU allocation. Select Unlimited to specify no upper limit. Shares CPU shares for this virtual machine in relation to the parent’s total. Sibling virtual machines share resources according to their relative share values bounded by the reservation and limit. Select Low, Normal, or High, which specify share values respectively in a 1:2:4 ratio. Select Custom to give each virtual machine a specific number of shares, which express a proportional weight.
- Procedure (Adjust Latency Sensitivity)
- CPU affinity must be activated. Follow the steps below:
- In the vSphere Web Client go to the VM Settings tab.
- Choose the Options tab and select .
- Add entries for numa.nodeAffinity=0, 1, ..., where 0 and 1 are the processor socket numbers.
- vNIC must be of type 'vmxnet3' (or SR-IOV, see SR-IOV section for support details)
- Minimum of any one of the following vNICs:
- The First vNIC is the public (outside) interface, which must be an untagged interface.
- The Second vNIC is optional and acts as the private (inside) interface that can support VLAN tagging dot1q and Q-in-Q. This interface typically faces the PE router or L3 switch.
- Optional vNIC (if a separate management/OAM interface is required).
- Memory reservation is set to ‘maximum.’
- 16GB of memory (32GB RAM is required when enabling certificate-based authentication).
- 64 GB of virtual disk (96GB disk is required when enabling certificate- based authentication).
Note: Arista uses the above defined settings to obtain scale and performance numbers. Settings that do not align with the above requirements are not tested by Arista and can yield unpredictable performance and scale results.
- Latency Sensitivity must be set to 'High'.
- If using KVM:
- vNIC must be of 'Linux Bridge' type. (SR-IOV is required for high performance, see SR-IOV section for support details).
- 8 vCPUs (4vCPUs are supported but expect lower performance).
Important: All vCPU cores should be mapped to the same socket with the Cores per Socket parameter set to either 8 with 8 vCPUs, or 4 where 4 vCPUs are used.Note: Hyper-threading must be deactivated to achieve maximum performance.
- 16GB of memory (32GB RAM is required when enabling certificate- based authentication)
- Minimum of any one of the following vNICs:
- The First vNIC is the public (outside) interface, which must be an untagged interface.
- The Second vNIC is optional and acts as the private (inside) interface that can support VLAN tagging dot1q and Q-in-Q. This interface typically faces the PE router or L3 switch.
- Optional vNIC (if a separate management/OAM interface is required).
- 64 GB of virtual disk (96GB disk is required when enabling certificate- based authentication).
Firewall/NAT Requirements
- The firewall needs to allow outbound traffic from the SD-WAN Gateway to TCP/443 (for communication with SASE Orchestrator).
- The firewall needs to allow inbound traffic from the Internet to UDP/2426 (VCMP), UDP/4500, and UDP/500. If NAT is not used, then the firewall needs to also allow IP/50 (ESP).
- If NAT is used, the above ports must be translated to an externally reachable IP address. Both the 1:1 NAT and port translations are supported.
Use of DPDK on SD-WAN Gateways
To improve packet throughput performance, SD-WAN Gateways take advantage of Data Plane Development Kit (DPDK) technology. DPDK is a set of data plane libraries and drivers provided by Intel for offloading TCP packet processing from the operating system kernel to processes running in user space and results in higher packet throughput. For additional details, see https://www.dpdk.org/.
On VeloCloud hosted Gateways and Partner Gateways, DPDK is used on interfaces that manage data plane traffic and is not used on interfaces reserved for management plane traffic. For example, on a typical Arista hosted Gateway, eth0 is used for management plane traffic and would not use DPDK. In contrast, eth1, eth2, and eth3 are used for data plane traffic and use DPDK.
SD-WAN Gateway Installation Procedures
This section discusses the SD-WAN Gateway installation procedures.
- Create SD-WAN Gateway on SASE Orchestrator and make a note of the activation key.
- Configure SD-WAN Gateway on SASE Orchestrator.
- Create the cloud-init file.
- Create the VM in ESXi or KVM.
- Boot the SD-WAN Gateway VM and ensure the SD-WAN Gateway cloud-init initializes properly. At this stage, the SD-WAN Gateway should already activate itself against the SASE Orchestrator.
- Verify connectivity and deactivate cloud-init.
Pre-Installation Considerations
The VeloCloud Partner Gateway provides different configuration options. A worksheet should be prepared before the installation of the Gateway.
| SD-WAN Gateway |
|
| Hypervisor | Address/Cluster name |
| Storage | Root volume datastore (>40GB recommended) |
| CPU Allocation | CPU Allocation for KVM/Arista. |
| Installation Selections | DPDK—This is optional and enabled by default for higher throughput. If you choose to deactivate DPDK, contact Arista Customer Support. |
| OAM Network |
|
| ETH0 – Internet Facing Network |
|
| Handoff (ETH1)- Network |
|
| Console access |
|
| NTP |
|
SD-WAN Gateway Section
Most of the SD-WAN Gateway section is self-explanatory.
| SD-WAN Gateway |
|
Creating a Gateway and Getting the Activation Key
- In the Operator portal, select the Gateway Management tab and go to Gateway Pools in the left navigation pane. The Gateway Pools page appears. Create a new SD-WAN Gateway pool. For running SD-WAN Gateway in the Service Provider network, check the Allow Partner Gateway checkbox. This will enable the option to include the partner gateway in this gateway pool.
Figure 1. Creating a Gateway Pool 
- In the Operator portal, select and create a new gateway and assign it to the pool. The IP address of the gateway entered here must match the public IP address of the gateway. If unsure, you can run curl ipinfo.io/ip from the SD-WAN Gateway which will return the public IP of the SD-WAN Gateway.
Figure 2. Creating a New Gateway 
- Make a note of the activation key and add it to the worksheet.
Activate Partner Gateway Mode
- In the Operator portal, select and select the SD-WAN Gateway. Check the Partner Gateway check box to activate the Partner Gateway.
Figure 3. Activating a Gateway
There are additional parameters that can be configured. The most common are the following:- Advertise
0.0.0.0/0with no encrypt – This option will enable the Partner Gateway to advertise a path to Cloud traffic for the SAAS Application. Since the Encrypt Flag is off, it will be up to the customer configuration on the business policy to use this path or not. - The second recommend option is to advertise the SASE Orchestrator IP as a
/32with encrypt.This will force the traffic that is sent from the Edge to the SASE Orchestrator to take the Gateway Path. This is recommended since it introduces predictability to the behavior that the SD-WAN Edge takes to reach the SASE Orchestrator.
- Advertise
Networking

The diagram above is a representation of the SD-WAN Gateway in a 2-ARM deployment. In this example, we assume eth0 is the interface facing the public network (Internet) and eth1 is the interface facing the internal network (handoff or VRF interface).
For the Internet Facing network, you only need the basic network configuration.
| ETH0 – Internet Facing Network |
|
For the Handoff interface, you must know which type of handoff you want to configure and the Handoff configuration for the Management VRF.
| ETH1 – HANDOFF Network |
|
| Console access |
|
In order to access the Gateway, a console password and/or an SSH public key must be created.
Cloud-Init Creation
The configuration options for the gateway that we defined in the worksheet are used in the cloud-init configuration. The cloud-init config is composed of two main configuration files, the metadata file and the user-data file. The meta-data contains the network configuration for the Gateway, and the user-data contains the Gateway Software configuration. This file provides information that identifies the instance of the SD-WAN Gateway being installed.
Below are the templates for both meta_data and user_data files. Network-config can be omitted and network interfaces will be configured via DHCP by default.
Fill the templates with the information in the worksheet. All #_VARIABLE_# must be replaced, and check any #ACTION#
instance-id: #_Hostname_# local-hostname: #_Hostname_#
version: 2 ethernets: eth0: addresses: - #_IPv4_Address_/mask# gateway4: #_IPv4_Gateway_# nameservers: addresses: - #_DNS_server_primary_# - #_DNS_server_secondary_# search: [] routes: - to: 0.0.0.0/0 via: #_IPv4_Gateway_# metric: 1 eth1: addresses: - #_MGMT_IPv4_Address_/Mask# gateway4: 192.168.152.1 nameservers: addresses: - #_DNS_server_primary_# - #_DNS_server_secondary_# search: [] routes: - to: 0.0.0.0/0 via: #_MGMT_IPv4_Gateway_# metric: 13
#cloud-config hostname: #_Hostname_# password: #_Console_Password_# chpasswd: {expire: False} ssh_pwauth: True ssh_authorized_keys: - #_SSH_public_Key_# velocloud: vcg: vco: #_VCO_# activation_code: #_Activation_Key# vco_ignore_cert_errors: false
The default username for the password that is configured in the user-data file is vcadmin. Use this default username to login to the SD-WAN Gateway for the first time.
sed s/[”“]/'"'/g /tmp/user-data > /tmp/user-data_new
Create ISO File
Once you have completed your files, they need to be packaged into an ISO image. This ISO image is used as a virtual configuration CD with the virtual machine. This ISO image, called vcg01-cidata.iso, is created with the following command on a Linux system:
genisoimage -output vcg01-cidata.iso -volid cidata -joliet -rock user-data meta-data network-config
If you are on a MAC OSX, use the command below instead:
mkisofs -output vcg01-cidata.iso -volid cidata -joliet -rock {user-data,meta-data,network-config}
This ISO file which we will call #CLOUD_INIT_ISO_FILE# is going to be used in both OVA and VeloCloud installations.
Install SD-WAN Gateway
You can install SD-WAN Gateway on Arista and KVM.
- SR-IOV
- Linux Bridge
- OpenVSwitch Bridge
- On KVM, see Install SD-WAN Gateway on KVM.
- On Arista, see Install SD-WAN Gateway on Arista.
Enable SR-IOV on Arista
Enabling SR-IOV on Arista is an optional configuration.
Prerequisites
- Intel 82599/82599ES
- Intel X710/XL710
To enable SR-IOV on Arista, perform the following steps:
Install SD-WAN Gateway on Arista
discusses how to install the SD-WAN Gateway OVA on Arista.
If you decide to use SR-IOV mode, then you can optionally enable SR-IOV on Arista. To enable the SR-IOV on Arista, see Enable SR-IOV on Arista.
- Select the ESXi host, go to Actions, and then Deploy OVF Template. Select the SD-WAN Gateway OVA file provided by Arista and select Next.
Figure 9. Deploying the OVF Template 
Review the template details in Step 4 (Review details) of the Deploy OVA/OVF Template wizard as shown in the image below.
Figure 10. Reviewing Installation Details 
- For the Select networks step, the OVA comes with two pre-defined networks (vNICs).
Table 11. Pre-defined Networks vNIC Description Inside This is the vNIC facing the PE router and is used for handoff traffic to the MPLS PE or L3 switch. This vNIC is normally bound to a port group that does a VLAN pass-through (VLAN=4095 in vswitch configuration). Outside This is the vNIC facing the Internet. This vNIC expects a non-tagged L2 frame and is normally bound to a different port group from the Inside vNIC. Figure 11. Selecting Networks 
- For the Customize template step, do not change anything. This is when you use vApp to configure the VM. We will not use vApp in this example. Select Next to continue with deploying the OVA.
Figure 12. Customizing the Template 
- Once the VM is successfully deployed, return to the VM and select Edit Settings. Two vNICs are created with adapter type = vmxnet3.
Figure 13. Editing VM Settings 
- (Optional for SR-IOV) This step is required only if you plan to use SR-IOV. Because the OVA by default creates the two vNICs as vmxnet3, we will need to remove the two vNICs and re-add them as SR-IOV.
Figure 14. Adding Network Adaptors 
When adding the two new SR-IOV vNICs, use the same port group as the original two vmxnet3 vNICs. Make sure the Adapter Type is SR-IOV passthrough. Select the correct physical port to use and set the Guest OS MTU Change to Allow. After you add the two vNICs, select OK.
Figure 15. Adding the Adaptor Type 
- As SD-WAN Gateway is a real-time application, you need to configure the Latency Sensitivity to High.
Figure 16. Enabling Logging 
- Refer to Cloud-init Creation. The Cloud-init file is packaged as a CD-ROM (iso) file. You need to mount this file as a CD-ROM.
Note: You must upload this file to the datastore.
Figure 17. Adding CD/DVD Drive 
- Start the VM.
Activate SR-IOV on KVM
To enable the SR-IOV mode on KVM, perform the following steps.
Prerequisites
- Intel 82599/82599ES
- Intel X710/XL710
- Enable SR-IOV in BIOS. This will be dependent on your BIOS. Login to the BIOS console and look for SR-IOV Support/DMA. You can verify support on the prompt by checking that Intel has the correct CPU flag.
cat /proc/cpuinfo | grep vmx - Add the options on Bboot (in /etc/default/grub).
GRUB_CMDLINE_LINUX="intel_iommu=on"- Run the following commands: update-grub and update-initramfs -u.
- Reboot
- Make sure iommu is enabled.
velocloud@KVMperf3:~$ dmesg | grep -i IOMMU [ 0.000000] Command line: BOOT_IMAGE=/vmlinuz-3.13.0-107-generic root=/dev/mapper/qa--multiboot--002--vg-root ro intel_iommu=on splash quiet vt.handoff=7 [ 0.000000] Kernel command line: BOOT_IMAGE=/vmlinuz-3.13.0-107-generic root=/dev/mapper/qa--multiboot--002--vg-root ro intel_iommu=on splash quiet vt.handoff=7 [ 0.000000] Intel-IOMMU: enabled …. velocloud@KVMperf3:~$
- Based on the NIC chipset used, add a driver as follows:
- For the Intel 82599/82599ES cards in SR-IOV mode:
- Download and install ixgbe driver from the Intel website.
- Configure ixgbe config (tar and sudo make install).
velocloud@KVMperf1:~$ cat /etc/modprobe.d/ixgbe.conf - If the ixgbe config file does not exist, you must create the file as follows.
options ixgbe max_vfs=32,32 options ixgbe allow_unsupported_sfp=1 options ixgbe MDD=0,0 blacklist ixgbevf - Run the update-initramfs -u command and reboot the Server.
- Use the modinfo command to verify if the installation is successful.
velocloud@KVMperf1:~$ modinfo ixgbe and ip link filename: /lib/modules/4.4.0-62-generic/updates/drivers/net/ethernet/intel/ixgbe/ixgbe.ko version: 5.0.4 license: GPL description: Intel(R) 10GbE PCI Express Linux Network Driver author: Intel Corporation, <이 이메일 주소가 스팸봇으로부터 보호됩니다. 확인하려면 자바스크립트 활성화가 필요합니다.> srcversion: BA7E024DFE57A92C4F1DC93
- For the Intel X710/XL710 cards in SR-IOV mode:
- Download and install i40e driver from the Intel website.
- Create the Virtual Functions (VFs).
echo 4 > /sys/class/net/device name/device/sriov_numvfs - To make the VFs persistent after a reboot, add the command from the previous step to the "/etc/rc.d/rc.local" file.
- Deactivate the VF driver.
echo “blacklist i40evf” >> /etc/modprobe.d/blacklist.conf - Run the update-initramfs -u command and reboot the Server.
- For the Intel 82599/82599ES cards in SR-IOV mode:
Validating SR-IOV (Optional)
You can quickly verify if your host machine has SR-IOV enabled by using the following command:
lspci | grep -i Ethernet
Verify if you have Virtual Functions:
01:10.0 Ethernet controller: Intel Corporation 82599 Ethernet Controller Virtual Function(rev 01)
Install SD-WAN Gateway on KVM
discusses how to install the SD-WAN Gateway qcow on KVM.
Pre-Installation Considerations
KVM provides multiple ways to provide networking to virtual machines. The networking in libvirt should be provisioned before the VM configuration. There are multiple ways to configure networking in KVM. For a full configuration of options on how to configure Networks on libvirt, see the following link:
https://libvirt.org/formatnetwork.html
- SR-IOV (This mode is required for the SD-WAN Gateway to deliver the maximum throughput specified by Arista)
- OpenVSwitch Bridge
If you decide to use SR-IOV mode, enable SR-IOV on KVM. To enable the SR-IOV on KVM, see Activate SR-IOV on KVM.
SD-WAN Gateway Installation Steps on KVM
- Copy the QCOW and the Cloud-init files created in the Cloud-Init Creation section to a new empty directory.
- Create the Network interfaces that you are going to use for the device.
Using SR-IOV: The following is a sample network interface template specific to Intel X710/XL710 NIC cards using SR-IOV.
<interface type='hostdev' managed='yes'> <mac address='52:54:00:79:19:3d'/> <driver name='vfio'/> <source> <address type='pci' domain='0x0000' bus='0x83' slot='0x0a' function='0x0'/> </source> <model type='virtio'/> </interfaceUsing OpenVSwitch: The following are the sample templates of a network interface using OpenVSwitch.git ./vcg/templates/KVM_NETWORKING_SAMPLES/template_outside_openvswitch.xml<?xml version="1.0" encoding="UTF-8"?> <network> <name>public_interface</name> <!--This is the network name--> <model type="virtio" /> <forward mode="bridge" /> <bridge name="publicinterface" /> <virtualport type="openvswitch" /> <vlan trunk="yes"> <tag id="50" /> <!--Define all the VLANS for this Bridge --> <tag id="51" /> <!--Define all the VLANS for this Bridge --> </vlan> </network>Create a network for inside_interface:
git ./vcg/templates/KVM_NETWORKING_SAMPLES/template_inside_openvswitch.xml
If you are using OpenVSwitch mode, then you have to verify if the basic networks are created and active before launching the VM.<network> <name>inside_interface</name> <!--This is the network name--> <model type='virtio'/> <forward mode="bridge"/> <bridge name="insideinterface"/> <virtualport type='openvswitch'></virtualport> <vlan trunk='yes'></vlan> <tag id='200'/> <!—Define all the VLANS for this Bridge --> <tag id='201'/> <!—Define all the VLANS for this Bridge --> <tag id='202'/> <!—Define all the VLANS for this Bridge --> </network>Note: This validation step is not applicable for SR-IOV mode as you do not create any network before the VM is launched.Figure 18. Validating the Network 
- Edit the VM XML file. There are multiple ways to create a Virtual Machine in KVM. You can define the VM in an XML file and create it using libvirt, using the sample VM XML template specific to OpenVSwitch mode and SR-IOV mode.
The following is a sample template of a VM which uses OpenVSwitch interfaces. Use this template by making edits, wherever applicable.vi my_vm.xml
The following is a sample template of a VM which uses SR-IOV interfaces. Use this template by making edits, wherever applicable.<?xml version="1.0" encoding="UTF-8"?> <domain type="kvm"> <name>#domain_name#</name> <memory unit="KiB">8388608</memory> <currentMemory unit="KiB">8388608</currentMemory> <vcpu>8</vcpu> <cputune> <vcpupin vcpu="0" cpuset="0" /> <vcpupin vcpu="1" cpuset="1" /> <vcpupin vcpu="2" cpuset="2" /> <vcpupin vcpu="3" cpuset="3" /> <vcpupin vcpu="4" cpuset="4" /> <vcpupin vcpu="5" cpuset="5" /> <vcpupin vcpu="6" cpuset="6" /> <vcpupin vcpu="7" cpuset="7" /> </cputune> <resource> <partition>/machine</partition> </resource> <os> <type>hvm</type> </os> <features> <acpi /> <apic /> <pae /> </features> <cpu mode="host-passthrough" /> <clock offset="utc" /> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>restart</on_crash> <devices> <emulator>/usr/bin/kvm-spice</emulator> <disk type="file" device="disk"> <driver name="qemu" type="qcow2" /> <source file="#folder#/#qcow_root#" /> <target dev="hda" bus="ide" /> <alias name="ide0-0-0" /> <address type="drive" controller="0" bus="0" target="0" unit="0" /> </disk> <disk type="file" device="cdrom"> <driver name="qemu" type="raw" /> <source file="#folder#/#Cloud_ INIT_ ISO#" /> <target dev="sdb" bus="sata" /> <readonly /> <alias name="sata1-0-0" /> <address type="drive" controller="1" bus="0" target="0" unit="0" /> </disk> <controller type="usb" index="0"> <alias name="usb0" /> <address type="pci" domain="0x0000" bus="0x00" slot="0x01" function="0x2" /> </controller> <controller type="pci" index="0" model="pci-root"> <alias name="pci.0" /> </controller> <controller type="ide" index="0"> <alias name="ide0" /> <address type="pci" domain="0x0000" bus="0x00" slot="0x01" function="0x1" /> </controller> <interface type="network"> <source network="public_interface" /> <vlan> <tag id="#public_vlan#" /> </vlan> <alias name="hostdev1" /> <address type="pci" domain="0x0000" bus="0x00" slot="0x11" function="0x0" /> </interface> <interface type="network"> <source network="inside_interface" /> <alias name="hostdev2" /> <address type="pci" domain="0x0000" bus="0x00" slot="0x12" function="0x0" /> </interface> <serial type="pty"> <source path="/dev/pts/3" /> <target port="0" /> <alias name="serial0" /> </serial> <console type="pty" tty="/dev/pts/3"> <source path="/dev/pts/3" /> <target type="serial" port="0" /> <alias name="serial0" /> </console> <memballoon model="none" /> </devices> <seclabel type="none" /> </domain><?xml version="1.0" encoding="UTF-8"?> <domain type="kvm"> <name>#domain_name#</name> <memory unit="KiB">8388608</memory> <currentMemory unit="KiB">8388608</currentMemory> <vcpu>8</vcpu> <cputune> <vcpupin vcpu="0" cpuset="0" /> <vcpupin vcpu="1" cpuset="1" /> <vcpupin vcpu="2" cpuset="2" /> <vcpupin vcpu="3" cpuset="3" /> <vcpupin vcpu="4" cpuset="4" /> <vcpupin vcpu="5" cpuset="5" /> <vcpupin vcpu="6" cpuset="6" /> <vcpupin vcpu="7" cpuset="7" /> </cputune> <resource> <partition>/machine</partition> </resource> <os> <type>hvm</type> </os> <features> <acpi /> <apic /> <pae /> </features> <cpu mode="host-passthrough" /> <clock offset="utc" /> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>restart</on_crash> <devices> <emulator>/usr/bin/kvm-spice</emulator> <disk type="file" device="disk"> <driver name="qemu" type="qcow2" /> <source file="#folder#/#qcow_root#" /> <target dev="hda" bus="ide" /> <alias name="ide0-0-0" /> <address type="drive" controller="0" bus="0" target="0" unit="0" /> </disk> <disk type="file" device="cdrom"> <driver name="qemu" type="raw" /> <source file="#folder#/#Cloud_ INIT_ ISO#" /> <target dev="sdb" bus="sata" /> <readonly /> <alias name="sata1-0-0" /> <address type="drive" controller="1" bus="0" target="0" unit="0" /> </disk> <controller type="usb" index="0"> <alias name="usb0" /> <address type="pci" domain="0x0000" bus="0x00" slot="0x01" function="0x2" /> </controller> <controller type="pci" index="0" model="pci-root"> <alias name="pci.0" /> </controller> <controller type="ide" index="0"> <alias name="ide0" /> <address type="pci" domain="0x0000" bus="0x00" slot="0x01" function="0x1" /> </controller> <interface type='hostdev' managed='yes'> <mac address='52:54:00:79:19:3d'/> <driver name='vfio'/> <source> <address type='pci' domain='0x0000' bus='0x83' slot='0x0a' function='0x0'/> </source> <model type='virtio'/> </interface> <interface type='hostdev' managed='yes'> <mac address='52:54:00:74:69:4d'/> <driver name='vfio'/> <source> <address type='pci' domain='0x0000' bus='0x83' slot='0x0a' function='0x1'/> </source> <model type='virtio'/> </interface> <serial type="pty"> <source path="/dev/pts/3" /> <target port="0" /> <alias name="serial0" /> </serial> <console type="pty" tty="/dev/pts/3"> <source path="/dev/pts/3" /> <target type="serial" port="0" /> <alias name="serial0" /> </console> <memballoon model="none" /> </devices> <seclabel type="none" /> </domain> - Launch the VM by performing the following steps:
- Ensure you have the following three files in your directory as shown in the following sample screenshot:
- qcow file- vcg-root
- cloud-init- vcg-test.iso
- Domain XML file that defines the VM- test_vcg.xml, where test_vcg is the domain name.)
Figure 19. Launching the VM 
- Define VM.
velocloud@KVMperf2:/tmp/VeloCloudGateway$ virsh define test_vcg.xml Domain test_vcg defined from test_vcg.xml - Set VM to autostart.
velocloud@KVMperf2:/tmp/VeloCloudGateway$ virsh autostart test_vcg - Start VM.
velocloud@KVMperf2:/tmp/VeloCloudGateway$ virsh start test_vcg
- Ensure you have the following three files in your directory as shown in the following sample screenshot:
- If you are using SR-IOV mode, after launching the VM, set the following on the Virtual Functions (VFs) used:
- Set the spoofcheck off.
ip link set eth1 vf 0 spoofchk off - Set the Trusted mode on.
ip link set dev eth1 vf 0 trust on - Set the VLAN, if required.
ip link set eth1 vf 0 vlan 3500
Note: The Virtual Functions configuration step is not applicable for OpenVSwitch (OVS) mode. - Set the spoofcheck off.
- Console into the VM.
virsh list Id Name State ---------------------------------------------------- 25 test_vcg running velocloud@KVMperf2$ virsh console 25 Connected to domain test_vcg Escape character is ^]
- Deactivate GRO (Generic Receive Offload) on physical interfaces (to avoid unnecessary re-fragmentation in SD-WAN Gateway).
ethtool –K <interface> gro off tx off - Deactivate CPU C-states (power states affect real-time performance). Typically, this can be done as part of kernel boot options by appending
processor.max_cstate=1or just deactivate in the BIOS. - For production deployment, vCPUs must be pinned to the instance. No oversubscription on the cores should be allowed to take place.
Post-Installation Tasks
This section discusses post-installation and installation verification steps.
If everything worked as expected in the installation, you can now login to the VM.
Configure Handoff Interface in Data Plane
VeloCloud Gateway Network Configuration
In the example featuring figure below (VRF/VLAN Hand Off to PE), we assume eth0 is the interface facing the public network (Internet) and eth1 is the interface facing the internal network (customer VRF through the PE).BGP peering configuration is managed on the VCO on a per customer/VRF basis under “Configure > Customer”. Note that the IP address of each VRF is configurable per customer. The IP address of the management VRF inherits the IP address configured on the SD-WAN Gateway interface in Linux.

A management VRF is created on the SD-WAN Gateway and is used to send periodic ARP refresh to the default Gateway IP to determine the next-hop MAC. It is recommended that a dedicated VRF is set up on the PE router for this purpose. The same management VRF can also be used by the PE router to send IP SLA probe to the SD-WAN Gateway to check for SD-WAN Gateway status (SD-WAN Gateway has stateful ICMP responder that will respond to ping only when its service is up). BGP Peering is not required on the Management VRF. If a Management VRF is not set up, then you can use one of the customer VRFs as Management VRF, although this is not recommended.
Remove Blocked Subnets
By default, the SD-WAN Gateway blocks traffic to 10.0.0.0/8 and 172.16.0.0/14. We will need to remove them before using this SD-WAN Gateway because we expect SD-WAN Gateway to be sending traffic to private subnets as well. If you do not edit this file, when you try to send traffic to blocked subnets, you will find the following messages in /var/log/gwd.log
2015-12-18T12:49:55.639 ERR [NET] proto_ip_recv_handler:494 Dropping packet destined for 10.10.150.254, which is a blocked subnet. 2015-12-18T12:52:27.764 ERR [NET] proto_ip_recv_handler:494 Dropping packet destined for 10.10.150.254, which is a blocked subnet. [message repeated 48 times] 2015-12-18T12:52:27.764 ERR [NET] proto_ip_recv_handler:494 Dropping packet destined for 10.10.150.10, which is a blocked subnet.
- On SD-WAN Gateway,
edit/opt/vc/etc/vc_blocked_subnets.jsonfile. You will find that this file first has the following.[ { "network_addr": "10.0.0.0", "subnet_mask": "255.0.0.0" }, { "network_addr": "172.16.0.0", "subnet_mask": "255.255.0.0" } ] - Remove the two networks. The file should look like below after editing. Save the change.
[ ] - Restart the SD-WAN Gateway process by
sudo /opt/vc/bin/vc_procmon restart.
Upgrade Gateway
This section describes how to upgrade a SD-WAN Gateway installation.
Authenticate Software Update Package Via Digital Signature
The software installer in the VeloCloud Orchestrator version 4.3.0 and higher now has the ability to authenticate the software update package using a digital signature.
Prior to upgrading to a newer version of the software, make sure the public key exists to verify the package. The known public key location to verify signature is as follows,
/var/lib/velocloud/software_update/keys/software.key. Alternatively, the key can be provided on the command line using the --pubkey parameter.
The current release public key is:
-----BEGIN PUBLIC KEY----- MHYwEAYHKoZIzj0CAQYFK4EEACIDYgAEbjZ08w3RNJvuOICBp8fysU/3opLejsrP pArA1IyKeUzU0U31MU4kPcLdggojobNfs3i1kvyvGvprEmfGYWzc3dXUyT9Tv73C lVgYPLNd/nOxJsXomROKogfvJdYFuy4/ -----END PUBLIC KEY----
If the key is missing or the signature cannot be verified, the Operator will be notified that the package is untrusted with an option to proceed or not proceed.
To skip verification, use the --untrusted parameter.
If running in batch mode or not on the terminal, the installation is aborted unless the --untrusted option is specified on the command line.
By default, the installer will run in interactive mode and may issue prompts. For automated scripts, use the --batch parameter to suppress prompts.
Upgrade Procedures
- Download the VeloCloud Gateway update package.
- Upload the image to the VeloCloud Gateway system (using, for example, the scp command). Copy the image to the following location on the system:
/var/lib/velocloud/software_update/vcg_update.tar - Connect to the VeloCloud Gateway console and run:
sudo /opt/vc/bin/vcg_software_update
Activate Replacement Partner Gateway
Gateway activation keys do not have the same default 30 day lifetime as Edges. In fact, a Gateway activation key has an infinite lifespan. If an on-premises Gateway fails and you wish to replace it with a newly built Gateway using the same name and IP address, you can use the same activation key that was used on the original Gateway.
As a result, for most Gateway issues, the quickest method of recovery is to spin up a new VM and register it to the Orchestrator using the failed Gateway’s activation key. This saves you a lot of time as the Orchestrator will push the existing configuration onto this new instance. Most Partners prefer this approach over configuring a new Gateway from scratch.
Before you can use this Gateway replacement method, you must adjust the system property gateway.activation.validate.deviceID and set the value to false. To do this you or another Operator with a Superuser role must go to and search for gateway.activation and inspect gateway.activation.validate.deviceID. If the Value is already false as in the screenshot below, then you are ready for the next steps. If the Value is true, then a Gateway reactivation will not work, and you need to modify this system property by selecting it.


gateway.activation.validate.deviceID system property is set to False and find that you cannot reactivate your Partner Gateway, you can reach out to the Arista Support team and they will assist you in changing that system property on your Orchestrator.These are the steps to activate a replacement Partner Gateway:
Custom Configurations
This section discusses custom configurations.
NTP Configuration
NTP configuration involves editing the /etc/ntpd.conf file.
OAM Interface and Static Routes
If Gateways are to be deployed with an OAM interface, complete the following steps.
OAM- SR-IOV with vmxnet3 or SR-IOV with VIRTIO
It is possible in some installations to mix and match and provide different interface types for the Gateway. This generally happens if you have an OAM without SR-IOV. This custom configuration requires additional steps since this causes the interfaces to come up out of order.
Record the MAC address of each interface.
Arista: After creating the machine, go to Edit Settings and copy the Mac address.

KVM: After defining the VM, run the following command:

Special Consideration When Using 802.1ad Encapsulation
It seems certain that 802.1ad devices do not populate the outer tag EtherType with 0x88A8. Special change is required in user data to interoperate with these devices.
Assuming a Management VRF is configured with S-Tag: 20 and C-Tag: 100, edit the vrf_vlan section in / etc/ config/ gatewayd as follows. Also, define resp_mode to 1 so that the Gateway will relax its check to allow Ethernet frames that have incorrect EtherType of 0x8100 in the outer header.
SNMP Integration
This section discusses how to configure SNMP integration.
For additional information on SNMP configuration, see Net-SNMP documentation. To configure SNMP integration:
Custom Firewall Rules
This section discusses how to modify custom firewall rules.
To modify local firewall rules, edit the following file: /etc/iptables/rules.v4
*filter :INPUT ACCEPT [0:0] -A INPUT -p udp -m udp --source 127.0.0.1 --dport 161 -m comment --comment "allow SNMP port" -j ACCEPT :FORWARD ACCEPT [0:0] :OUTPUT ACCEPT [0:0] COMMIT
Restart netfilter service:
service netfilter-persistent restart service vc_process_monitor restart