Overview

This guide is intended for properly trained service personnel and technicians who need to install selectedArista Networks Data Center Switches.

Scope

This guide covers the following devices:

2RU Switches
DCS-7280R4-32PE DCS-7280R4K-32PE DCS-7280R4-32DE DCS-7280R4K-32DE
DCS-7280R4-64QC-10PE DCS-7280R4K-64QC-10PE    

 

Important:

Only qualified personnel should install, service, or replace this equipment.

 

Seul le personnel qualifié doit installer, service, ou remplacer cet équipement.

Receiving and Inspecting the Equipment

Upon receiving the switch, inspect the shipping boxes and record any external damage. Retain packing materials if you suspect that part of the shipment is damaged; the carrier may need to inspect them.

If the boxes were not damaged in transit, unpack them carefully. Ensure that you do not discard any accessories that may be packaged in the same box as the main unit.

Inspect the packing list and confirm that you received all listed items. Compare the packing list with your purchase order. The Parts List provides a list of components included with the switch.

Installation Process

This section discusses the task required to install and use the switch.

  1. Select and prepare the installation site (Site Selection).
  2. Assemble the installation tools (Tools and Parts Required for Installation).
  3. Attach the mounting brackets and install the switch in an equipment rack (Rack Mounting the Switch).
  4. Connect the switch to the power source and network devices (Cabling the Switch).
  5. Configure the switch (Configuring the Switch).

     

    Important:

    Class 1 Laser Product: This product has provisions to install Class 1 laser transceivers which provide optical coupling to the communication network. Once a Class 1 laser product is installed, the equipment is a Class 1 Laser Product. The customer is responsible for selecting and installing the Class 1 laser transceiver and for insuring that the Class 1 AEL (Allowable Emission Limit) per EN/IEC 60825, CSA E60825-1, and Code of Federal Regulations 21 CFR 1040 is not exceeded after the laser transceiver have been installed. Do not install laser products whose class rating is greater than 1. Refer to all safety instructions that accompanied the transceiver prior to installation. Only Class 1 laser devices, certified for use in the country of installation by the cognizant agency are to be utilized in this product.

     

    Produit Laser de classe 1: Ce produit a des dispositions pour installer des émetteurs-récepteurs de laser de classe 1 qui offre de couplage au réseau de communication optique.Une fois un produit laser de classe 1 est installé, l'équipement est un produit Laser de classe 1 (Appareil à Laser de Classe 1).Le client est responsable pour sélectionner et installer l'émetteur/récepteur de laser de classe 1 et pour assurer que la classe 1 AEL (limite d'émission admissible) par EN/IEC 6-825, CSA E60825-1, et Code des règlements fédéraux 21 CFR 1040 ne soit pas dépassée après avoir installé l'émetteur/récepteur de laser. Ne pas installer des appareils à laser dont la cote de classe est supérieure à 1.Voir toutes les consignes de sécurité qui ont accompagné l'émetteur-récepteur avant l'installation. Seuls appareils laser de classe 1 certifiés pour une utilisation dans le pays d’installation par l’organisme compétent doivent être utilisées dans ce produit.

     

    Important:

    Ultimate disposal of this product should be handled in accordance with all national laws and regulations.

     

    L'élimination finale de ce produit doit être effectuée conformément à toutes les lois nationales etrèglements.

Obtaining Technical Assistance

Any customer, partner, reseller, or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways.

Note:

No user serviceable parts inside. Refer all servicing to qualified service personnel.

 

Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien qualifié.

Specifications

This guide covers a list of specifications for Arista data center modular switches and components.

Table 1. Switch Specifications (Dimensions and Weights)
Switch Size (W x H x D) Weight
2RU switches
DCS-7280R4-32PE 48.3 x 8.8 x 62.9 cm

(19 x 3.50 x 24.8 inches)

22.9 kg

(50.4 lbs.)

DCS-7280R4K-32PE 48.3 x 8.8 x 62.9 cm

(19 x 3.50 x 24.8 inches)

22.9 kg

(50.4 lbs.)

DCS-7280R4-32DE 48.3 x 8.8 x 62.9 cm

(19 x 3.50 x 24.8 inches)

22.9 kg

(50.4 lbs.)

DCS-7280R4K-32DE 48.3 x 8.8 x 62.9 cm

(19 x 3.50 x 24.8 inches)

22.9 kg

(50.4 lbs.)

DCS-7280R4-64QC-10PE 48.3 x 8.8 x 62.9 cm

(19 x 3.50 x 24.8 inches)

22.8 kg

(50.2 lbs.)

DCS-7280R4K-64QC-10PE 48.3 x 8.8 x 62.9 cm

(19 x 3.50 x 24.8 inches)

22.8 kg

(50.2 lbs.)

 

 

Table 2. Switch Specifications (Operational and Storage)
Switch Operating1 Temperature Storage Temperature Operating Altitude1 Relative Humidity
All 0° to 40°C

(32° to 104°F)

-25° to 70°C

(-13° to 158°F)

0 to 3,000 meters

(0 to 10,000 feet)

5 to 90%

(non-condensing)

1 The use of high power transceivers may require temperature or altitude de-rating.

 

 

Table 3. Switch Specifications (Power Input)
Power Source PSU Models Ratings
Power Input: AC
  PWR-3211-HV1 200 - 277 VAC, 18 A 50/60 Hz
PWR-2411-AC 200 - 240 VAC, 14 A, 50/60 Hz
Power Input: DC
  PWR-3211-HV1 240 to 380 VDC, 18 A (at 200 VAC)
PWR-3211-DC -48 to -60 VDC, 73 A
PWR-2411-DC -48 to -60 VDC, 55 A

1 Check switch datasheets for compatibility with the PWR-3211-HV PSU.

 

Note: Use only the PSU models supported by the switch. Some switches described in this guide could use power supplies that may no longer be available. Contact your local Arista representative for more information.

 

Table 4. Switch Specifications (Power Draw)
Switch Power Draw (Typical / Maximum) Supported Power Supply
2RU switches
DCS-7280R4-32PE 805 W / 1874 W PWR-3211-HV

PWR-3211-DC

DCS-7280R4K-32PE 805 W / 1874 W PWR-3211-HV

PWR-3211-DC

DCS-7280R4-32DE 805 W / 1874 W PWR-3211-HV

PWR-3211-DC

DCS-7280R4K-32DE 805 W / 1874 W PWR-3211-HV

PWR-3211-DC

DCS-7280R4-64QC-10PE 630 W / 1317 W PWR-2411-AC

PWR-2411-DC

DCS-7280R4K-64QC-10PE 630 W / 1317 W PWR-2411-AC

PWR-2411-DC