- Written by Srinivasan Viswanathan
- Posted on 3月 23, 2026
- Updated on 11月 10, 2026
- 2431 Views
The pre-VESPA wireless GW campus solution offered redundancy by means of having primary and secondary wireless GWs that can be configured in the Access Points (APs). APs monitor the primary tunnel's health by means of periodic ICMP messages, and switch to the secondary tunnel when the primary becomes unreachable, and traffic convergence is delayed until this failover happens.
- Written by Ashwini Kumar
- Posted on 9月 4, 2025
- Updated on 3月 12, 2026
- 3647 Views
Arista’s CCS-710XP series of ethernet switches consist of CCS-710XP-12TH-2S SKU. CCS-710XP-12TH-2S is a 12 port 1000BASE-T PoE & 2-port SFP+ fanless switch device rich with networking features suited for campus deployments.
- Written by Anand
- Posted on 4月 17, 2026
- Updated on 4月 17, 2026
- 1402 Views
This feature enables efficient cross-domain communication in a multi-domain deployment where the Layer 2 leaf VTEPs don't have arp learning bridged configured. Without this feature, cross-domain ARP requests must be flooded across all domains, creating significant overhead in large multi-domain deployments.
- Written by Mitchell Jameson
- Posted on 8月 24, 2020
- Updated on 6月 30, 2026
- 15067 Views
Typical WiFi networks utilize a single, central Wireless LAN Controller (WLC) to act as a gateway between the wireless APs and the wired network. Arista differentiates itself by allowing the wireless network to utilize a distributed set of aggregation switches to connect APs to the wired network. This feature allows a decentralized and distributed set of aggregation switches to bridge wireless traffic on behalf of the set of APs configured to VXLAN tunnel all traffic to those aggregation switches, or their “local” APs.
- Written by Utkarsha Verma
- Posted on 2月 18, 2021
- Updated on 4月 14, 2025
- 16976 Views
Arista campus switches allow extensive and fine grained hardware based flow tracking and management features. They
- Written by Aaron Bamberger
- Posted on 6月 5, 2023
- Updated on 9月 20, 2023
- 11077 Views
Enabling “Proxy ARP/ND for Single Aggregation (AG) VTEP Campus Deployments without EVPN” allows an aggregation VTEP to proxy reply to a VXLAN-encapsulated ARP request/NS when the ARP/NS target host is remote and the ARP/ND binding is already learned by the AG VTEP.
- Written by Scott Bailey
- Posted on 5月 23, 2022
- Updated on 7月 31, 2025
- 12447 Views
The CCS-750X-48ZXP is a 48 port 10GBASE-T linecard, capable of several full-duplex link speeds to support connecting to a variety of compatible devices of varying capabilities. All supported linkup speeds on this card can be automatically selected during the linkup process using IEEE 802.3 Clause 28 auto-negotiation. Note that IEEE 802.3 also allows for speeds lower than 1Gbps to link up without clause 28 auto-negotiation.