- Written by Rahul Vasist
- Posted on 6月 11, 2019
- Updated on 6月 20, 2019
- 9801 Views
ASU, or Accelerated Software Upgrade, is a feature to minimize traffic loss when upgrading from one ASU supported EOS
- Written by Rahul Vasist
- Posted on 11月 6, 2019
- Updated on 11月 13, 2019
- 9737 Views
ASU (or Accelerated Software Upgrade) is a feature that will minimize traffic loss when upgrading from one ASU
- Written by Peter Lam
- Posted on 9月 30, 2015
- Updated on 1月 2, 2025
- 14916 Views
Leaf Smart System Upgrade (SSU) provides the ability to upgrade the EOS image with minimal traffic disruption.Note: It is possible that SSU shutdown and bootup are not supported in the same image. If a product has shutdown support in image A and bootup support in a later image B, then SSU upgrade cannot be performed from image A to any images earlier than image B, including image A itself. However, upgrading from image A to image B onwards is allowed.
- Written by Karan Jagjit Kumar
- Posted on 6月 29, 2023
- Updated on 3月 12, 2025
- 8234 Views
Smart System Upgrade (SSU) provides the ability to upgrade the EOS image with minimal traffic disruption. This is an existing feature on many fixed system products. This resource will outline the SSU feature in reference to CCS-720DP, CCS-722XPM, CCS-720XP-96ZC2, CCS-720XP-48TXH-2C, and DCS-7010TX.
- Written by Joshua Portelance
- Posted on 8月 31, 2023
- Updated on 10月 13, 2023
- 6317 Views
Smart System Upgrade (SSU) provides the ability to upgrade the EOS image with minimal traffic disruption. This is an existing feature on many fixed system products. This resource will outline the SSU feature in reference to CCS-750XP, which is the first modular product to support SSU.
- Written by Fei Rao
- Posted on 12月 20, 2024
- Updated on 12月 20, 2024
- 1442 Views
There are two types of reload on a switch running EOS, normal reload and Smart System Upgrade (SSU). Scheduled normal reload is supported via ‘reload in’ command, to perform a normal reload after a specified delay. It asks for saving unsaved configuration changes and confirmation in order to schedule the reload. Scheduled SSU is supported via ‘reload fast-boot in’ command. However, after scheduling an SSU reload, if there are unsaved configuration changes, or saved configuration changes which block an SSU reload, the scheduled reload will be aborted at scheduled time.
- Written by Dongping Zhu
- Posted on 3月 3, 2023
- Updated on 5月 6, 2025
- 7730 Views
Leaf Smart System Upgrade (SSU) provides the ability to upgrade the EOS image with minimal traffic disruption. To perform the SSU, Spanning Tree Protocol (STP) should either be configured as MSTP or Rapid-PVST mode or should be disabled. Meanwhile, all ports should be configured with admin edge ports (i.e., all ports are supposed to connect to host only) and the BPDU guard should be enabled for all edge ports.